Fumex FA5-1 Series Operation Manual Download Page 3

 

CONTROLS

 

 

On/Off Switch 

 
Simple  one  touch  controls 

–  The  green  light  above  the  POWER  button  will  illuminate  confirming  power  to  the 

unit.       

 

Blower/Fan 

 
The  FA5-1  utilizes  a  variable  speed  blower  with  8  speed  settings.  Press  the  up  /down  arrows  to  increase  and 

decrease the blower speed.  Blower gradually increases in speed as 

“Up” arrow is pressed - some slight delay is 

normal operation. Speed is indicated by the bar graph located above 

“BLOWER” label.  A green light will indicate 

that the blower is operating 

– no light indicates a blower failure or loss of power.  

 

Filter monitoring 

 
The FA5-1 utilizes independent pressure differential switches to monitor the status of each particulate filter (the 

Pre-filter and the HEPA filter).  Filter status is indicated by the corresponding bar graph 

(“PRE” for part# FA540B; 

“HEPA” for part# FA500). The bar graph will increase in 20% increments until the filter is “loaded”. Red lights will 
indicate that a filter change is necessary. 

 

The FA5-1 contains a VOC sensor to detect odors/gases in the exhaust stream.  The system continually monitors 

the  exhaust  stream  which  is  indicated  on  the  bar  graph  labeled 

“GAS”.    When  the  gas/odor  filter  becomes 

saturated, and breakthrough of the VOC occurs 

the “GAS” warning light will illuminate. 

 

GENERAL FILTER CARE   

 

Fumex  FA5-1  air  purifiers  feature  a  multi-stage  filtration  system  designed  to  remove  a  wide  range  of  pollutants 

from the process plume in an extremely efficient, and cost-effective manner.  Once the warning lights illuminate, 

filters should be checked, and clogged filters replaced.   

 

   

S T A N D A R D   F I L T E R S :  

 

Part # FA540B 

– Pre-filter Assembly 

The  pre-filter  assembly  is  the  first  stage  in  the  filtration  process.    Unique  design  minimizes  operator/ 

maintenance personnel exposure to contaminants. 

 

Replacement: 

Filter life  is  highly dependent  on  the  amount  and  size  of  the  captured  particulates.  Average  service  life  is 4-6 

months. 

 
 
 
 
 

Reviews: