Page 1: ...th any solid state speed control device WARNING For general ventilating use only Do not use to exhaust hazardous or explosive materials or vapors WARNING Use only a 15 Amp fuse CAUTION Do not operate without having all filters in place Do not operate any fan with a damaged cord or plug Discard fan or return to an authorized service facility for examination and or repair Do not run cord under carpe...
Page 2: ...f the cabinet L o c a t i n g t h e a i r c l e a n e r Placing the FA2 as close as possible to the pollution source reduces the amount of ducting needed reduces back pressure lowers power consumption and improves overall performance Placement should minimize hose length and the number of bends Use capture hoods with high efficiency entry whenever possible Make sure to allow top access to the filt...
Page 3: ...ase in 20 increments until the filter is loaded Red lights will indicate that a filter change is necessary The FA2 contains a VOC sensor to detect odors gases in the exhaust stream The system continually monitors the exhaust stream which is indicated on the bar graph labeled GAS When the gas odor filter becomes saturated and breakthrough of the VOC occurs the GAS warning light will illuminate GENE...
Page 4: ...d in industrial manufacturing processes GENERAL MAINTENANCE 1 The blower motor s is a sealed unit 24 000 hr MTBF rated It is permanently lubricated and does not require oiling keep it free of dust accumulations to prevent overheating 2 Remove any loose accumulations of dust debris from the air filter chamber periodically This product employs overload protection fuse A blown fuse indicates an overl...
Page 5: ...ired or replaced at our option free of charge provided it has not been misused abused or otherwise damaged and is returned PREPAID to Fumex LLC 1150 Cobb International Pl Kennesaw GA 30152 There are no warranties which extend beyond the descriptions set forth in this warranty notwithstanding any knowledge of Fumex LLC regarding the use or uses intended to be made of goods proposed changes or addit...
Page 6: ...e relays have been activated the unit will only start by applying the proper voltage to the start stop relay RELAY DE ACTIVATION PROCEDURES FOR FA2 UNITS 1 To de activate the relays so the remote feature cannot be used the software will need to be reprogramed via a flash drive with a configuration file fumex ini and the USB port on the control board Contact Fumex to acquire the correct configurati...