DRIFTSINSTRUKTIONER
OPERATION INSTRUCTIONS
0522
Produktion:
Autotech SPS
AB Boliden
S GB
D
W2
U1
U2
V1
V2
W1
L1
L2
L3
(L3)
(L1)
Y
W2
U1
U2
V1
V2
W1
L1
L2
L3
(L3)
(L1)
Z2
U1
U2
Z1
L1
N
Z2
U1
U2
Z1
L1
N
3
Temperature
Warning!
When the fan operates the fanhousing takes the
temperature of the conveyed media. If that temperature
exceeds 50°C the fan must be protected from direct
contact to prevent burninjury.
4
Electrical connection
Warning!
Electrical connection must be made by skilled labour
only. The drivemotor should be protected with an
overload switch.
5
Permitted applications
Warning!
F-fans are not to be used for conveying aggressive, toxic
or air with high humidity or gas or explosive air-gas
mix.
6
Sound level
The sound pressure level is not the same over the fans
whole range. In some cases it is necessary to use a
silencer. We recommend the user to check the sound
pressure level.
D
Installation
1
Transportation
Check all parts for damage during transportation and
that the impeller runs free inside the housing. The
blowers are to be installed in weather-protected places
and are not to be stored outdoors unprotected. Mount
hoisting hook carefully, and do only use lifting
arrangements with sufficient strength.
2
Arrangements and assembling
Mount the fan horizontally or vertically in a weather-
protected place. Make sure that the fan is protected from
vibration and shock. Supply open inlet and dis-charge
openings with guards according to valid regulations.
Make sure that the drive motor is supplied with sufficient
ventilation. The permitted maximum temperature of
surroun-dings is 40°C.
3
Electrical connection
Attention
!
The operations described in this part is to be made by
skilled labour only. Connect the fan in accordance with
the wiring diagram in the terminal box. The respec-tive
VDE regulations and the directions of the local power
supply company are to be complied with.
The fan is equipped with a drivemotor for single- or
three-phase AC. The motor should be protected with an
over-load switch. Connection to earth is to be found in
the terminal box.
Connection of three-phase AC unit
(Low voltage
D
-connection) (High voltage Y-connnection)
Connection of single-phase AC unit
The arrows are seen from the inlet side
4
Inspection of rotation direction
Start up the fan for a short moment, inspect the rotation
direction. The rotation direction on the impeller must
be in accordance with the arrows on the motor. If not,
move the L1 and L3 phases for three-phase operation
or check the wiring circuit in the terminal box for single-
phase operation. Incorrect rotation direction will cause
reduced capa-city of the fan.
E
Start of operation
If the rated current indicated on the rating plate is being
exceeded during opera-tion, it should be checked whether
the available supply voltage and frequency are in
accordance with the embossed data. Some blowers
cannot be ope-rated with free airflow (see catalogue).
The drivemotor is sized for the power requirements
when the fan operates in the filled part of the capacity
curve. At lower resistance the working range moves out
to the pointed part of the capacity curve and the airvolume
and current increase. The motor will be overloaded with
possible overheating as a consequence. To avoid overload
it is possible to fit a throttle flap on the inlet- or
dischargeside. Do not expose the fan to vibrations and
shock.
F
Maintenance
F blowers are equipped with enclosed grooved ball
bearings which do not need lubrication. The grease
filling is sufficient for the whole service life of the
bearings.
Attention!
Repair work on blowers should be done in the factory
only. We do not take any responsibility for repairs made
by third parties.
G
Spare parts list
When ordering spare parts please state size of blower
and part number in ac-cordance with the spare parts list.
H
EC Manufacturer Declaration
Manufacturer:
Fumex AB
Verkstadsvägen 2
S-931 61 Skellefteå
Sweden
We certify that the product to which this certificate
relates, is in conformity with the standards or standard-
setting documents listed below. If a modification of the
unit (s) is made without our approval, this declaration
becomes invalid.
Description of the product:
High pressure fans type F
Relevant regulations to which these products
correspond:
EC Machine directive 98/37/EG
EC Low voltage directive LVD 73/23/EEC
Electromagnetic compability EMC 89/336/EEC,
92/31/EEC, 93/68/EEC
Source references of harmonized standards:
LVD
EN 60034
EMC EN 55014-1, EN 60555-1
MD
EN 292-1, EN 60204-1 (safety of Machinery)
Starting operation of this machinery part is not allowed
as long as it is not assembled into the main installation
respectively not all necessary safety devices have been
installed which fulfil the requirements of the EC directive
for machines with regard to safety and health.