background image

C 600

HT

Manual

Summary of Contents for C 600HT

Page 1: ...C 600HT Manual...

Page 2: ...EC Declaration of Conformity We declare under our sole responsibility that the product described in this document conforms to the standards or documents having the force of standards specified below I...

Page 3: ...ion with the result that clothes hair loose objects and body parts can be easily drawn into the fan Never allow any part of the body or loo se fitting clothing to be in the vicinity of the inlet The f...

Page 4: ...d if these have tripped due to the motor overheating they will return to their origi nal position after cooling down Make sure nothing can cause a hazard in the event of a temporary power failure If t...

Page 5: ...ng the product or ordering spare parts refer to the data in dicated on the nameplate in the first instance 3 2 2 Labelling 1 Fumex logo 2 Labels symbols relating to safe use of the fan 3 Nameplate Arr...

Page 6: ...partly completed machinery Before the fan is put into service it must comply with the requirements of Machinery Directive 2006 42 EC After installation the unit must meet the requirements of standard...

Page 7: ...n viewed from the motor shaft as shown in Fig 5 Other mounting methods require the approval of Fumex AB The mounting points of the fan are at the inlet flange outlet flange and the motor feet if prese...

Page 8: ...nominal value for any of the fan s phases Measured vibrations do not exceed permissible values The type and model match the order 5 Commissioning 5 1 Before commissioning Check to ensure the followin...

Page 9: ...Fault on one of the motor phases The motor is exceeding the maximum permissible speed Too little resistance in the airflow 3 Fan fails to start Contact between impeller and fan housing Foreign object...

Page 10: ...lan ce in the impeller The vibrations need to be measured and if found to have increased the cause must be established and rectified The maximum value for the vibrations at the motor ball bearing perp...

Page 11: ...rews are correctly tightened Safety equipment works properly The value for insulation resistance of the motor is correct The structure is fully intact without damaged components due to e g abrasion 9...

Page 12: ...he motor not on drawing are made of galvanised steel Fasteners not on drawing are made of stainless steel For execution of the seals sealant and sealing tape e g EPDM have been used A complete list of...

Reviews: