Ref / Pt.No: 294130
Operating Instructions for Safe Use
Fullwood M²erlin
Revision: C
Date: 24-Mar-17
294130
Page 72 of 81
61
error
BUCKET ERROR
Bucket system has problems
reaching Bucket or Park
position.
No Data
No Data
No Data
62
error
IDENTIFICATION
ERROR
Multiple cows in crate not
identified in time.
Broken antenna /
broken ID circuit
board / wrong
configuration.
The system has been
unable to identify X
animals in a row.
Verify/exchange antenna
(wiring) / verify / exchange
ID circuit board / verify
power supply to ID circuit
board.
63
error
DATABASE
ERROR
Cow separation, maximum no.
of animals with unknown tags
reached.
No Data
No Data
No Data
64
error
AIR PRESSURE
Air pressure switch is disabled.
An error will be
generated, all
activities will be
stopped and Merlin
will go into off-line
mode.
The input activated by
the air pressure
monitoring unit is
deactivated.
Check air pressure and
reset alarm.
65
error
LIGHTNING
PROTECTION
Lightning protection input is
disabled.
An error will be
generated, all
activities will be
stopped and Merlin
will go into off-line
mode.
The input activated by
the air pressure
monitoring unit is
deactivated.
Check lightning protection
and reset alarm.
66
error
NO COW
TIMEOUT
No cow being milked for longer
than 1 hour without Merlin being
off-line or in pause (Adjustable
in Crystal 2.7).
An error will be
generated and Merlin
will go into pause
mode.
No cow alarm setting
has expired.
Check the system and
reset alarm.
67
warning
CRYSTALAB
_ERROR
The crystalab has produced
errors which aren't expected
every milking, if this continues
every milking Crystalab is
probably broken.
Info messages are
generated, System
will continue milking.
The crystalab has
produced errors which
aren't expected every
milking, if this continues
every milking Crystalab
is probably broken.
Check CrystaLab.
68
error
MILKPUMP
_INVERTER
The milk pump inverter is in
error and not working.
An error will be
generated, all
activities will be
stopped and Merlin
The input activated by
the milk pump inverter is
deactivated.
Check milk pump inverter
and reset alarm.