8. Modified sine wave specifications

Model No. 

PDA1000-12N 

PDA1800-12N 

PDA3000-12N 

PDA1000-24N 

PDA1800-24N 

PDA3000-24N 

Max. surge power 

2000W 

3600W 

6000W 

Continuous power 

1000W 

1800W 

3000W 

AC output voltage 

230VAC 

Regulation 

±8% 

±5% 

DC input voltage 

10 ~ 16V (12V) 
20 ~ 32V (24V) 

Output wave form 

Modified sine wave 

Frequency 

50Hz ± 3% 

Efficiency 

> 85% 

No load current draw 

≤ 0.6A (12V) 

≤ 0.5A (12V) 

≤ 0.6A (12V) 

≤ 0.3A (24V) 

≤ 0.3A (24V) 

≤ 0.3A (24V) 

Temperature protection 

55 ± 5ºC (131 ± 9 ºF) 

Input low voltage alarm 

YES 

Input low voltage shut down 

YES 

Input high voltage protection 

YES 

Output short circuit protection 

YES 

DC and AC isolated 

YES 

Remote control optional 

NO 

YES 

Dimensions (L *W * H) in mm 

295*179*82.5 

530*274*105 

570*274*105 

Net weight (kg) 

2.4 

7.3 

8.3 

Gross weight (kg) with cable 

2.7 

8.0 

9.4 

Note: Specifications subject to change without notice 

User’s manual 

- 10 - 

PDAxx00S / PDA1000/1800/3000 

Summary of Contents for PDA1000

Page 1: ...tion 3 Soft start technology improves reliability List of contents 1 Important safety instructions 1 2 Where to install 1 3 Inverter operation 2 4 Terminal installation diagram 3 5 Modified sine wave models 4 6 Pure sine wave models 6 7 Remote control Liquid crystal display 9 8 Modified sine wave specifications 10 9 Pure sine wave specifications 11 10 Inverter troubleshooting guide 14 11 Warranty ...

Page 2: ...n making the cable connections since current may flow and charge capacitors in the inverter This is normal Do not make cable connections in the presence of flammable fumes it may result in explosion and or fire Shock Hazard Before proceeding further carefully check the inverter is not connected to any batteries and that all wiring is disconnect from any electrical sources Do not connect the output...

Page 3: ...es not have to deliver the starting currents for all the loads at once The ON OFF switch turns the control circuit in the power inverter on and off The inverter input voltage ranges are shown as below PDA300S PDA600S PDA1200S PDA1800S PDA2500S PDA3000S PDA1000 PDA1800 PDA3000 9 5V to 16 0V for 12V models 10 0V to 16 0V for 12V models 19 0V to 32 0V for 24V models 20 0V to 32 0V for 24V models 38 0...

Page 4: ...ill blow internal fuse and may damage inverter permanently Damage caused by reversed polarity is not covered by the warranty User s manual 3 PDAxx00S PDA1000 1800 3000 Step Modified sine wave models Pure sine wave PDA1000 Parts Cable terminals Spring washer Screw Insulator To cover the terminals by the insulator Screw the terminals tightly ...

Page 5: ...Front view Rear view Case Thermal cooling fan Battery terminals Connect to battery or other power source is positive Red is negative Black Reverse polarity connection will blow internal fuse and may damage inverter permanently Do not obstruct allow at least 15 cm 6 inches for airflow Ventilation window Case ON OFF SWITCH AC receptacle PDA1000 DC INPUT Red Black Grounding ...

Page 6: ...ous appliances including resistant load traditional lighting load computer load etc User s manual 5 PDAxx00S PDA1000 1800 3000 Front view DC Input DC INPUT Red Black Rear view Grounding European type Please keep switch in the OFF position during installation Connect to battery or other power source is positive Red is negative Black Reverse polarity connection will blow internal fuse and may damage...

Page 7: ... etc Small kitchen appliances coffe makers toasters etc Lighting products fluorescent and incandescent lights high pressure sodium lamps etc Home entertainment electronics TV VCR video games etc Model PDA300S PDA600S PDA1200S PLEASE re turn on the inverter when you change the frequency User s manual 6 PDAxx00S PDA1000 1800 3000 PDA300S PDA600S PDA1200S Rear view PDA300S Fan DC Input 50 60HZ Switch...

Page 8: ...uit 1 2 4 5 6 7 1 2 4 5 5 AC Output hard wiring 6 AC Input hard wiring for bypass model only 7 Breaker for bypass model only Rear view DC Input 1 2 Battery terminals Connect to battery or other power source is positive Red is negative Black Reverse polarity connection will blow internal fuse and may damage inverter permanently 4 Ventilation window Do not obstruct allow at least 6 inches 15cm for a...

Page 9: ...acket optional accessory Bracket hast two parts rear and frame 1 With the frame only it must be a hole in the wall 2 With both frame and rear user just can screw the bracket on the wall It is not necessary a hole in the wall FRONT VIEW Frame Rear AC OUTPUT AC INTPUT BREAKER Please press to restart if open circuit ELECTRICAL SHOCK HAZARD RISQUE DE CHOC ÉLECTRIQUE ...

Page 10: ...OFF Load watts Input DC volt Power Saving Mode Battery Capacity 20W Load Output waveform 1 Inverter Mode Standby Display 2 Power Saving Mode Signal Display 3 Power Saving Count Down Time 10sec Display 4 Power Saving Count Down Time 30sec Display 5 Battery low volt protection 6 Battery high volt protection 7 Overtemp Protection 9 AC input Bypass Mode Display 8 Overload or short circuit protection F...

Page 11: ...ncy 85 No load current draw 0 6A 12V 0 5A 12V 0 6A 12V 0 3A 24V 0 3A 24V 0 3A 24V Temperature protection 55 5ºC 131 9 ºF Input low voltage alarm YES Input low voltage shut down YES Input high voltage protection YES Output short circuit protection YES DC and AC isolated YES Remote control optional NO YES Dimensions L W H in mm 295 179 82 5 530 274 105 570 274 105 Net weight kg 2 4 7 3 8 3 Gross wei...

Page 12: ...e Frequency 50Hz 60Hz 3 Efficiency 87 No load current draw 0 6A 12V 0 9A 12V 1 1A 12V 0 3A 24V 0 5A 24V 0 6A 24V 0 2A 48V 0 3A 48V 0 3A 48V Temperature protection 55 5ºC 131 9 ºF Input low voltage alarm YES Input low voltage shut down YES Input high voltage protection YES Output short circuit protection YES DC and AC isolated YES THD Distortion 2 Dimensions L W H in mm 260 129 82 5 285 179 82 5 43...

Page 13: ...ing mode 0 12A 12V 0 06A 24V 0 03A 48V Inverter would re start automatically from power saving mode when load is higher than 10W Efficiency 85 Battery low alarm 10 5 0 5V 12V 21 1V 24V 42 2V 48V Battery low shut down 10 0 5V 12V 20 1V 24V 40 2V 48V Overvoltage protection 16 0 5V 12V 32 1V 24V 61 2V 48V Overtemperature protection 55 5ºC 131 9 ºF Short circuit protection Shut off Battery polarity re...

Page 14: ...nal Model No PDA1800S 12N PDA2500S 12N PDA3000S 12N PDA1800S 24N PDA2500S 24N PDA3000S 24N PDA1800S 48N PDA2500S 48N PDA3000S 48N DC no load current under normal mode 1 0A 12V 0 5A 24V 0 25A 48V DC no load current under power saving mode 0 4A 12V 0 2A 24V 0 1A 48V Low AC input voltage transfer to inverter mode 180VAC 5 Low AC input voltage recovery to AC mode 190VAC 5 High AC input voltage transfe...

Page 15: ...the inverter Check the wiring Reverse DC polarity Check battery fuse and the installation Replace the inverter Damage caused by reversed polarity is not covered by the warranty Low battery alarm on all the time Poor battery condition Charge or change battery Poor DC wiring Use proper cables and check connection Poor DC terminal connections Use proper tool No output voltage and overtemp indicator o...

Page 16: ...emoved The supplier is not liable for any incidental consequential or other damages arising from the use cost of removal installation or troubleshooting of the customer s electrical systems Repair or replacement are your sole remedies and shall not be liable for damages whether direct incidental special or consequential even though cause by negligence or other fault This is only warranty and the c...

Reviews: