Fullwat LIR18650-34 Quick Start Manual Download Page 3

w w w . f u l l w a t . c o m

LIR18650-34

 

 

Li-ion cylindrical rechargeable battery

  3. General specifications

NO.

Item

Parameter

3.1

Normal capacity

3350mAh (at @0.2C discharge)

Minimum capacity

3250mAh (at @0.2C discharge)

Nominal capacity is measured by the discharge at 0.2C to 2.5V end voltage after standard fully 

charged according to specification at 25ºC

3.2

Maximum charge voltage

4.20V±0.03V

3.3

Average working voltage 

[email protected] 

3.4

Standard charge method (25ºC±2ºC)

Constant current and constant voltage (CC/CV) 

Current

0l2C (670mA)

Voltage

4.2V

End current

67mmA±5mA

3.5

Maximum charge current 

(not for cycle)

  0ºC ≤ T ≤ 10ºC

0.1C (335mA)

10ºC ≤ T ≤ 20ºC

0.2C (670mA)

20ºC ≤ T ≤ 45ºC

0.3C (1005mA)

3.6

Charge time

Standard charge

6.0h

Rapid charge

4.0h

3.7

Standard discharge

Constant current (CC)

Current

0.2C (650mA)

End voltage

2.5V

3.8

Maximum discharge current 

(not for cycle)

-20ºC ≤ T ≤ 20ºC

1.0C(3350mA)

20ºC ≤ T ≤ 45ºC

2.0C(6700mA)

3.9

Cycle life

500th cycle ≥70% of 1

st

 Capacity (25ºC±2ºC, 4.2V-2.5V)

If charged and discharged at high rate and high 

temperature (≥35ºC) frequently, cell cycle life will be 

shorten. If charged and discharged at high temperature 

(>45ºC) frequently, cell safety may be occurred.

3.10

Weight of bare cell

Max. 50g

3.11

Operating environmental temperature

Charge

   0ºC ~ 45ºC

Discharge

-20ºC ~ 45ºC

3.12

Storagetemperature 

(for shipping state)

  1 month:   -20~45ºC 

  3 months: -20~ 35ºC 

12 months: -20~ 20ºC

Summary of Contents for LIR18650-34

Page 1: ...w w w f u l l w a t c o m LIR18650 34 Li ion cylindrical rechargeable battery...

Page 2: ...LIR18650 34 Li ion cylindrical rechargeable battery 1 Scope This product specification has been prepared to specify the Cylindrical Lithium ion Cell 2 Cell dimensions fig 1 Item Specification D 18 4 0...

Page 3: ...rrent not for cycle 0 C T 10 C 0 1C 335mA 10 C T 20 C 0 2C 670mA 20 C T 45 C 0 3C 1005mA 3 6 Charge time Standard charge 6 0h Rapid charge 4 0h 3 7 Standard discharge Constant current CC Current 0 2C...

Page 4: ...ng shall be terminated when the charging current has tapered to 0 02C 6 1 2 Charging shall consist of charging at a 0 3C constant current rate until the cell voltage reaches 4 2V The cell shall then b...

Page 5: ...equirements of Table 2 Table 2 10 C 0 C 25 C 45 C 70 80 100 95 7 SAFETY 7 1 External short circuiting Test at 25 C Cell charged per standard charge method is to be short circuited by connecting the po...

Page 6: ...floor by the positive and negative terminal down Wait for 1h Criteria No Fire No Explosion 8 Packaging Loading 100 cells per box 2 boxes per case for a total of 200 cells 9 Others Any matter not incl...

Page 7: ...e end voltage must be over 2 5V 1 2 2 Discharge temperature range should be 20 C 45 C see spec 3 8 If surface temperature exceeds 55 degrees the discharge must be stopped 1 3 Storage Any storage cell...

Page 8: ...ture protection Set the temperature protection of pack according to the cell use condition in SPEC Battery pack should have cell voltage balancing function and cell imbalance protection circuit Batter...

Page 9: ...ay fire smoke explode or cause heat 2 1 8 Don t charge near high temperatures If the battery is charged near the high temperature the battery can not be recharged due to the protection line In this ca...

Page 10: ...e if the battery has an abnormal smell heat or rust please contact the supplier 2 3 7 Keep away from flammable materials during charging and discharging May cause fire smoke explosion or cause heat 2...