background image

  5. General performance 

No.  Item 

Test methods and condition 

Criteria

5.1 

0.2C Capacity  

After standard charging, rest battery for 10min, 

≥300min

   

 

then discharging at 0.2C to voltage 3.0V,

   

 

recording the discharging time.   

 

5.2 

Cycle life 

Constant current 1.0C charge to 4.2V, then constant  

≥300times

   

 

voltage charge to current declines to 0.01C, rest 10min,

   

 

constant current 1.0C discharge to 3.0V 

rest 10min.

   

 

Repeat above steps till continuously discharging capacity

   

 

Higher than 80%of the Initial Capacities of the Cells

5.3 

Capability of 

20±5ºC, After standard charging, rest the battery 28days, 

≥240min

   

keeping electricity 

discharging at 0.2C to voltage 3.0V, recording

   

 

the discharging time. 

  6. Environment performance 

No.  Item 

Test methods and condition 

Criteria

6.1 

Discharge at  

After standard charging, rest the cells 4h at 60±2ºC, 

≥54min

   

high temperature 

then discharging at 1C to voltage 3.0V, recording 

   

 

the discharging time.  

6.2 

Discharge at 

After standard charging, rest the cells for 16h at -20±2ºC 

≥210min

   

low temperature 

then discharging at 0.2C to voltage 3.0V, recording 

   

 

the discharging time.  

6.3 

Thermal shock 

Put the cells in the oven. The temperature of the oven 

No fire, no smoke

   

 

is to be raised at 5±2ºC per minute to a temperature

   

 

of 130 ±2ºC and remains 30 minutes.  

  7. Safe characteristic

No.  Item 

Test methods and condition 

Criteria

7.1 

Over charge  

At 23±5ºC , charging cells with constant current 2C 

No fire, no smoke

   

testing 

to voltage 5V. Stop test till cells temperature 10ºC lower

   

 

than max temperature.  

7.2 

Over discharge 

At 23±5ºC, According to the requirements of standard 

No fire, no smoke,

   

testing 

charge, the cells will be discharge to cut-off voltage, 

no leakage

   

 

then connect with external load of 30 ohm for 24 hours.

7.3   Short-circuit 

At 23±5ºC, After standard charging, connect cells anode 

No fire, no smoke

   

testing 

and cathode by wire which impedance less than

   

 

80±20mΩ, keep 6h.

w w w . f u l l w a t . c o m

LIR14500-8

 

 

Rechargeable Lithium battery

Note

 - 

Above testing of safe characteristic must be with protective equipment.

Reviews: