Fullwat FUM-24 CBP Series User Manual Download Page 5

Fig.3  Power Supply / 2 Stage Charger Mode Application

H. Temperature Sensor 

The temperature sensor  is available as an optional accessory (ATS-5100) and is used to optimal charging over wide ambient
temperature range.
Fix the temperature sensor (optional accessory) in a position on the battery which is not affected by other cooling or heating
source. 
Plug in the temperature sensor before switch on the charger to activate the temperature control function, never plug in the charger
during charging.

Fig.4

 

Summary of Contents for FUM-24 CBP Series

Page 1: ...er serviceable parts inside Do not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective...

Page 2: ...Charger Power Supply Selection Slide Switch to set Charger to 3 Stage Charger or Power Supply Mode See Section G 3 Battery Type Selection Slide Switch to set charger for AGM Gel Wet and Calcium Calciu...

Page 3: ...tery condition fill up cells for wet battery clean battery poles Secure the battery charger in a well ventilated place make sure the mounting surface is flat and without soft covering material or loos...

Page 4: ...because only one setting of charging profile for both Two batteries are charged simultaneously and the battery with the lowest level gets most share of the current in the Bulk charge stage until it is...

Page 5: ...s used to optimal charging over wide ambient temperature range Fix the temperature sensor optional accessory in a position on the battery which is not affected by other cooling or heating source Plug...

Page 6: ...ours charging time Absorption light remains on all the time Wrong battery type selection eg charge gel battery with Calcium Calcium OR Wet type selection Total battery capacity is too high for dual ch...

Page 7: ...ted Output Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is Removed Short Circuit Recovers Automatically After F...

Reviews: