4. CONDITIONS OF USE

The Easiair

®

 2020 Powered  Air Kit is for use by trained personnel only. Training should be provided by the  

manufacturer, a qualified delegate, or a competent individual either in person or online.

Before assembling, visually inspect all components for damage or wear.

Ensure that all components are genuine and assembled according to this IFU manual. 

Ensure that the hood and belt are fitted appropriately to the user. The protective factor of the complete system is 
reduced if the seal of the headpiece is not fitted properly. Only if the headpiece is fitted correctly is the device able 
to operate effectively.

To avoid dislodging, the blower unit should be worn behind the wearer, in the small of their back.

The device is unlikely to cause allergic reactions to the wearer. However, in the unlikely event of a reaction, the  
user should immediately leave the contaminated area, remove the unit and seek medical advice.

It is essential that you do 

not:

 

  Attempt to modify, alter or tamper with any of the components in any way. 

  Touch any moving parts of the unit while in operation. 

  Allow water or other liquid substances into the device.

 

ATTENTION! 

 

If any of the conditions outlined in this IFU document are not kept or followed,  

your health may be at risk and your warranty protection in respect of the  

product(s) will be automatically invalidated.

The user is strongly advised to leave the contaminated area immediately if: 

  The warning alarm sounds. 

  Breathing becomes difficult. 

  Dizziness or distress occurs. 

  Any part of the system becomes damaged. 

  Airflow into the headpiece decreases or stops. 

  Contaminant can be smelt or tasted inside the headpiece.

Summary of Contents for Easiair 2020

Page 1: ...E RPE EXPERTS CE Approved to BS EN 12941 1998 A1 2003 A2 2008 Respiratory Protective Device Powered Air Kit incorporating a soft hood Class TH 3 P R SL Powered Air Kit Instructions For Use EASIAIR 20...

Page 2: ...espect of the product s for the specific details of such warranty cover This product is designed to protect your health and wellbeing Failure to comply with these user instructions may adversely affec...

Page 3: ...CONTENTS 1 Introduction 4 2 Range of applications 4 3 Approvals 4 4 Conditions of use 5 5 Unpacking 6 6 Before use 7 7 Assembly Donning 8 8 Cleaning Maintenance 11 9 Fault finding 13 10 Storage 14 11...

Page 4: ...complete protection the Easiair 2020 Powered Air Kit should be worn in conjunction with other personal protective equipment PPE appropriate for the intended task and environment This device is not cl...

Page 5: ...f their back The device is unlikely to cause allergic reactions to the wearer However in the unlikely event of a reaction the user should immediately leave the contaminated area remove the unit and se...

Page 6: ...age Easiair 2020 Powered Air Kit Item No Description Product Code 0 Easiair 2020 Blower Unit FSM48 1 Easiair 2020 Full Soft Hood c w Headgear FSM41 2 Easiair 2020 Breathing Hose FSM46 3 Easiair 2020 F...

Page 7: ...nit Attach the airflow indicator to the blower unit air outlet Switch on the device Holding the unit at eye level in a vertical position watch to see if the ball reaches the minimum flow rate level 6...

Page 8: ...s should be followed closely in order to maximise the efficiency of your device If your unit is not assembled or fitted correctly you may not be protected 7 1 Battery When supplied your unit s battery...

Page 9: ...ienist if you are unsure If a filter is to be reused store inside the unit to avoid dislodging contaminated matter Removing a soiled filter Twist the filter cover anti clockwise approximately 25mm unt...

Page 10: ...and compensate for any the state of the battery and any filter clogging If the microprocessor cannot maintain the appropriate airflow the unit will alarm Please see section 6 4 for more information P...

Page 11: ...n user ill health or even death Surface dirt Neutral detergent For surface dirt the Easiair 2020 Powered Air Kit can be wiped down with a soft cloth dampened with a neutral detergent solution Detach t...

Page 12: ...lowing table can be used to track maintenance of your device Serial Number Date Commissioned Maintenance required Date of Action Fit for use Name and Signature Cleanliness Yes No Scratches Yes No Valv...

Page 13: ...w Blocked air hose or airduct Check and remove blockage Leakage Check all seals connectors and the air hose Make sure that air cannot leak through holes or tears Battery is not charged enough Charge t...

Page 14: ...weight easy to use powered air purifying respirator kit It comes pre fitted with a reusable TH3 PR SL particulate filter affording reliable protection against viruses particulates and aerosols Approva...

Page 15: ...ull Support Healthcare Ltd undertake to exchange or repair without charge any part found to be defective within this period This guarantee does not affect your legal rights does not cover normal wear...

Page 16: ...Ltd Harrowden Court 66 80 Huxley Close Wellingborough Northamptonshire NN8 6AB United Kingdom Telephone 44 0 1933 672180 www fullsupportgroup com IM 1 042020 EU declaration of comformity present on t...

Reviews: