8.3 Descriptions
Allows to adjust the Microsol II plus sensors display message. The message selected will be used on
the
main screen to indicate which temperature is being displayed.
Wall-Link
1-Description S1
2-Description S2
3-
S3
Description
Sensor 1 description
Sensor 2 description
Sensor 3 description
8.5 Statistics
This function allows viewing on-screen statistics on wired communication, by displaying the number of
errors in requesting data from the Microsol II plus (
) and the number of errors in sending
functions (
).
Scan Err
Rx Err
Fun
sec.
-
msec.
msec.
msec.
x100ms
999
10
999
999
999
999
Time to scan for the Microsol II plus.
Number of communication failures before error indication
Delay for receiving data
Delay for receiving events schedule
Delay for sending functions
Time for displaying the SPC message
Description
Min.
Max.
Unit
Default
T01
T02
T03
T04
T05
T06
8.4 Timeouts
Allows adjusting the timings for the RF communications:
1
1
60
60
60
25
1
3
200
200
200
25
Aux 1status
Pump Aux1 Aux2
%
$
%&
9.2 Outputs status
Water pump status
Aux 2 status
$
%
$&
%&
Time
Tuesday
14:19
Day of week
Output off;
Output on;
Manual operated output off;
Manual operated output on;
9.1
Day of week and time
9. Other views
Pressing the key
repeatedly you can view other information from the Microsol II plus. The selected
visualization will remain on the display for 10 seconds and after this time it will return to the main screen.
The options available are:
S1: 104 S2:56.6
S3:39.6 Df:47.4
9.3 Viewing all temperatures
10. INDICATORS
Alarm of minimum temperature on the sensor S1
Alarm of maximum temperature on the sensor S1
Only with Microsol II plus from version 03
Wall-Link is unable to locate Microsol II plus at address 1;
High temperature alarm;
Freezing temperature alarm;
Sensor disconnected.
Min Temp
S1
Max
S1
Temp
Temperature at sensor 2
Temperature at sensor 3
Diferential temperature
(S1-S2)
Temperature at sensor 1
IMPORTANT
According to NBR5410 and IEC60364 standards:
Install
s on power supply.
protectors against overload
For more information contact our application eng. department through e-mail
or dial +55 51 3475 3308.
Mere
illustrative
image
Distribution
box
11. WIRING DIAGRAM
Microsol II plus
A
A
B
B
A B
RS-485
Wall-Link
Sensor 2
26.9$C
PUMP
AUX
1
M
IC
R
O
S
O
L
II
p
lu
s