background image

TC900EPWR04-02T

-14446

4. INDICATIONS AND KEYS

1

2

3

4

5

6

7

8

9

10

5.1 INSTALLATION - ELECTRICAL CONNECTIONS

6. OPERATIONS

6.1 Quick Access Menu Map

To access or navigate the quick access menu using the 

;

(short press) key while the controller is 

displaying the temperature. For every touch, the next function in the list is displayed. To confirm, use the 

/

(short press) key.

5

4

3

2

9

8

7

6

1

10

6.2 QUICK ACCESS KEYS MAP

When the controller is on temperature display, the following keys serve as a shortcut for the following 
functions:

1. DESCRIPTION

2. APPLICATION

3. TECHNICAL SPECIFICATIONS

For frozen products, it automates the defrost processes according to the need of installation (smart 
defrost). The ambient temperature control has a normal setpoint and an economic setpoint, apart from 
the  fast  freezing  function  and  alarm  functions  indicating  open  door.  Its  16A  relay  directly  controls 
compressors of up to 1HP and its defrost output has a current capacity of 10A.
It also features a digital filter, intended to simulate a mass increase in the ambient sensor (S1), thus 
increasing its response time (thermal inertia) and avoiding unnecessary drives of the compressor. It also 
includes a smart key, lock system and a control functions shutdown mode.

To drive inductive loads (motors and pumps) of up to 2HP, use the 

e

TC-900   2HP.

         

• Cold Storage Rooms   
• Display freezers

- Power supply: 

TC-900 E POWER: 115 or 230Vac ±10% (50/60Hz)

                           TC-900 EL POWER: 12 or 24Vac/dc ±10% 

- Control temperature: 

-50°C to 105°C / -58°F to 221°F 

- Operating temperature: 

0 to 50°C / 32 to 122°F

- Load current (outputs): COMP:

 12(8)A / 240Vac 1HP

                   DEFR: 

10A / 240Vac 1/4HP

                   FANS: 

5(3)A / 240Vac

- Operating humidity: 

10 to 85 %RH (without condensation)

- Dimensions: 

76 x 34 x 77 mm (WxHxD)

- Dimensions of the clipping for fixing of the instrument: 

71 ± 0,5 x 29 ± 0,5 mm (see item 5)

evolution

 

 

TC-900

 

e

 

POWER

 

Ver

.04

Connection 115 Vac

TC-900

 

e

 

POWER

/

<

<

<

<

Pressed for 2 seconds: Setpoint adjustment.
Short press: Displays process status.

Short press: display of minimum and maximum measurement records.

Enters the functions selection.

6.3 BASIC OPERATIONS

6.3.1Setting the desired temperature

To access the setpoints setup menu press 

/

 for 2 seconds. The message 

[SP,,]

 will appear on the 

display followed by the normal setpoint set value. Use the 

>

 or

<

 to modify the value and confirm by 

pressing 

/

.  Immediately,  the  message 

[SP-e]

  appears  indicating  the  setting  of  the  economic 

setpoint. Again, use the 

>

 or 

<

 keys to modify the value and confirm by pressing 

/

. Finally, the

   

[----]

 indication signals the setup completion. The setpoints can also be adjusted individually in the 

quick access menu.

TC-900 

POWER  

TC-900 

 

 

POWER

<

Pressed for 2 seconds: inhibits audible alarm.

<

Pressed for 2 seconds: when displaying records, it cleans the history.

1

5 6 7 8

2 3 4

9

10 11 12 13 14 15 16 17

Sensor S1

D1/S3

D2

Sensor S2

230 Vac

CO

MP

DE

FR

FA

NS / 

Panel (Front View)

Panel

(Side View)

Dimension of the clipping

for fixing of the 

instrument in panel

71 

 mm

± 0,5

29 

 mm

± 0,5

 

FOR INSTALLATIONS WHERE A SEALING IS REQUIRED TO AVOID LIQUID CONTACT, THE CUT FOR THE CONTROLLER 
MUST  BE  OF  70,5x29mm  MAXIMUM.  THE  SIDE  LOCKS  MUST  BE  FIXED  SO  IT  PRESSES  THE  RUBBER  SEALING 
AVOIDING INFILTRATION BETWEEN THE CUT AND THE CONTROLLER.

ATTENTION

DE

FR 2

;

Enters the quick access menu.

1

5 6 7 8

2 3 4

9

10 11 12 13 14 15 16 17

Sensor S1

D1/S3

D2

Sensor S2

CO

MP

DE

FR

Connection 230 Vac

115 Vac

FA

NS / 

DE

FR 2

5. INSTALLATION - ASSEMBLING

and

Control functions

shutdown

Functions

lockdown

Serial

programming

Protection

level

IP 65

FRONT

Fast Freezing

FAST FREEZING (ON/OFF)

;

TC-900

 

e

 

POWER

 

;

ECONOMIC SETPOINT(ON/OFF)

TC-900

 

e

 

POWER

 

;

DEFROST (ON/OFF)

TC-900

 

e

 

POWER

 

;

FUNCTIONS LOCKDOWN

TC-900

 

e

 

POWER

 

;

CONTROL FUNCTIONS
(ON/OFF)

TC-900

 

e

 

POWER

 

NORMAL SETPOINT 

;

TC-900

 

e

 

POWER

 

ECONOMIC SETPOINT

;

TC-900

 

e

 

POWER

 

MAX. AND MIN. TEMPERATURE
RECORD

;

TC-900

 

e

 

POWER

 

ERASE MAX. AND MIN. 
VALUES

;

TC-900

 

e

 

POWER

 

EXIT FUNCTION

;

TC-900

 

e

 

POWER

 

FUNCTION SELECTION

;

TC-900

 

e

 

POWER

 

*The 

sensor S1 (black) 

must be in the ambient.
*The 

sensor S2 (gray)

 must 

be placed in the evaporator 
through metallic cramp.

Set key
Quick Access Menu Key
Compressor output indication LED 
Fan/defrost indication LED 2
Defrost indication LED
Functions lock indication LED
Control functions shutdown indication LED
Temperature unit indication LED
Increase key
Decrease key

DIGITAL CONTROLLER FOR

REFRIGERATION AND DEFROST

Reviews: