6.3. Controller power supply

 

Use the pins according to table below, considering the set version:

6.4. Recommendations of IEC60364 standard

a) 

Install overload protectors in the controller supply.

b) 

Install transient suppressors – suppressor filter RC – in the circuit to increase the service life of the 

controller relay. See connection instructions of the filter on the previous page.

c) 

The sensor cables may be together, but not in the same conduit where the power supply of the 

controller and/or of the loads passes through.

7. FASTENING PROCEDURE 

a)

  Cut  out  the  panel  plate  (Image  V  -  item  13)  where  the  controller  shall  be  fastened,  with  sizes                             

X = 71±0,5 mm and Y = 29±0,5 mm; 

b)

 Remove side locks (Image VI - item 13): to do that, compress the central elliptical part (with the Full 

Gauge Controls logo) and displace the locks backwards;

c) 

Introduce the controller in the notch made on the panel, inwards;

d) 

Place the locks again and then displace them until they compress into the panel, fastening the 

controller to the housing (see arrow indication in Image VI - item 13); 

e) 

Perform the electric installation as described in item 6;

f) 

Adjust the parameters as described in item 8.

      ATTENTION: for installations requiring liquid tight sealing, the notch sizes for the controller 
installation should be no more than 70.5x29mm. The side locks should be fastened so that they 
press the sealing rubber avoiding infiltration between the notch and the controller.
Protector vinyl - Image VII (item 13)

It protects the controller when installed at a site subject to water spills, such as refrigerated counters. 
This adhesive vinyl is supplied with the instrument in the package. 

       IMPORTANT: Make the application only after completing the electrical connections.
a)

 Retreat the side locks (Image VI - item 13); 

b)

 Remove the protective film from the adhesive vinyl face;

c)

 Apply the vinyl over the entire upper part, bending the flaps, as indicated by the arrows - Image VII (item 

13);

d)

 Reinstall the locks.

NOTE: 

The vinyl is transparent, allowing visualization of the wiring system of the instrument.

Pins

RT-607E plus

RT-607EL plus

9 and 10

9 and 11

115 Vac
230 Vac

12 Vac/dc
24 Vac/dc

8. OPERATIONS

8.1. Quick Access Menu Map

To  access  or  browse  the  quick  access  menu  use  the 

;

key  (quick  touch)  while  the  controller  is 

displaying the temperature/time. With each touch the next function in the list is displayed. To confirm use 
the

/

 key (quick touch). See chapter 8.3 for more details. The map of functions is shown below:

8.3.2. Functions lock

The use of the functions lock brings greater security to the operation of the instrument. When it is active, 
the setpoint and other parameters can be visible to the user, but are protected against undue changes 

[,f15]

= 2 or you can block changes of control functions and leave the adjustment of the setpoint 

enabled 

[,f15]

=1. Using the 

;

key (quick touch), access the function 

[LOC,]

 in the quick access 

menu, confirm by pressing 

/

 (quick touch), then the message 

[no,,]

 will be displayed. After that 

keep  the 

>

  key  pressed  for  the  time  configured  for  the  functions  lock

[,f16]

until 

[LOC,]

is 

displayed.  The  message 

[On,,]

will  be  displayed  indicating  the  function  lock  is  activated  upon 

releasing the key.

RT-607

plus

To unlock, turn the controller off and then turn it on again with the 

>

 key pressed. Keep the key pressed 

until 

[LOC,]

is displayed. Keep the key pressed for 10 seconds and the message 

[OFF,]

 will be 

displayed indicating the function lock is deactivated upon releasing the key.

8.3.3. Control functions shutdown

Turning the control functions off allows for the controller to operate just as an indicator of temperature, 
keeping the control outputs and the alarms disconnected. Use of this feature is enabled or not by the 
control functions shutdown function

[,f17]

. When enabled, the control and alarms functions are 

turned off (

[CTRL][OFF,]

) or on (

[Ctrl][ON,,]

) through the quick access menu in the option  

[Ctrl]

. When the control functions are off the message 

[OFF,] 

will then be displayed alternately 

with the temperature and the other messages.
Except when 

[,f17]

 is equal to 3 or 4, in which case the display is switched off, keeping only the       

 .

icon on.

RT-607

plus

NOTE: 

It is also possible to switch the control functions on/off by pressing the 

;

 key for five seconds.

NOTE: 

When switching the control functions back on, 

RT-607

e

 

plus 

will continue to respect the 

functions  “

[,f06]

- Minimum thermostat output off time”.

8.3.4. Minimum and Maximum Temperature Record

Holding the

<

key down (quick touch) or also via the quick access menu, will cause the message 

[rEg,]

 to be displayed and the minimum and maximum temperatures to be recorded.

NOTE:

 If the

<

key is pressed while the events are being displayed the values will be reset and the 

message 

[rsEt]

 will be displayed.

NOTE: 

If the temperature sensor is disabled the messages 

[____]

and

[++++]

will be displayed.

8.3.5.View current date and time

Quickly pressing the

/

key makes possible to view the current date and time set in the controller. 

However  the  display  will  show  sequentially  the  current  day  (

[,--d]

),  month  (

[,--m]

),  year             

(

[,--y]

), weekday(

[day-]

), hour and minute (

[00:00]

) and if the preferred view set in 

[,f09] 

is 

[Hour]

, the temperature is also displayed. It is also possible to view the date and time through the 

quick access menu in the option 

[ClO,]

.

8.3.6. Manual triggering of event output

Pressing the key 

>

 for 10 seconds activates an event manually. This will be deactivated after the time 

set in the 

[,f09]

 function has elapsed. Pressing the key 

>

 again for 10 seconds deativavates the 

manual  operation.  When  activating  the  manual  trigger,  the 

[Eon,]

  message  and  the 

[EOff]

 

message are displayed when you turn off the manual trigger. It is also possible to perform the activation 
in the 

[man,]

 menu.

8.2. Quick access keys map

When controller is on temperature/time display mode, the following keys can be used as a shortcut for 
the following functions:

Hold down for 2 seconds: setpoint adjustment (desired temperature).

/

<

Hold down for 10 seconds: manual activation of the event output.

Quick touch: enter the quick access menu.

;

/

Quick touch: the current day, month, year, day of the week, hour, and minute/
                       temperature will be shown in sequence on the display.

Quick touch: display of the maximum and minimum measurements recorded.

<

Hold down for 2 seconds: clear history when records are being displayed.

<

Hold down for 5 seconds: control functions shutdown.

;

Enters function selection.

<

<

8.3. Basic operations

8.3.1. Adjusting setpoint (desired temperature)

Hold the 

/

 key down for 2 seconds until the message 

[SET,]

. is displayed. The adjusted control 

temperature will be displayed when the key is released. Use the 

<

or

>

 key to change the value and 

then press 

/

to save. The desired temperature can also be changed in the quick access menu, (see 

map on item 8.1).

;

FUNCTIONS LOCKDOWN

RT-607

plus

;

CONTROL FUNCTIONS 

SHUTDOWN

RT-607

plus

;

ADJUSTING DESIRED 

TEMPERATURE 

(SETPOINT)

RT-607

plus

EXIT FUNCTION

;

RT-607

plus

FUNCTION SELECTION

;

RT-607

plus

RT-607

plus

SWITCH THE EVENT OUTPUT

ON/OFF (MANUAL MODE)

;

RT-607

plus

DATE AND TIME VIEW

;

;

SCHEDULE EVENT 

PROGRAMMING

RT-607

plus

8.3.7. Date and time adjustment

Through  the  quick  access  menu,  the 

[CLO,]

  option  allows  you  to  set  controller  date  and  time. 

Use

<

or

>

to change the value and press

/

 when ready to save the configured value. If the date 

entered is invalid, the message 

[ECLO]

will be shown on the display.

Example 1 

(correct access code entered):

[,00d]

-

 

day  

[,00M]

-

 

month  

[,00Y]

-

 

year  

[00:00]

time

minute

flashing

IMPORTANT:

The controller has an auxiliary internal power supply to keep the clock running for at least 72 hours in 
case of a power cut. If the controller remains off for a long period of time, the message 

[ECLO]

may be 

displayed to indicate that the clock is not programmed. In this case, the date and time must be adjusted 
and the controller must be kept on for 10 hours to fully recharge the auxiliary power supply.

NOTE:

 To set the date and time through the menu outside the facilitated menu, it is necessary to enter 

the access code 

123

.

a) Press the key 

;

 (quick touch) simultaneously, 

<

 and 

>

 (quick touch), the 

[Code]

 option appears, 

asking you to entered the access code.
b) Press 

/

 and enter the access code 

123

 using the 

<

 or 

>

 keys, confirming with the key 

/

. The 

[Code]

 option will again appear.

c) Navigate through the menu using the 

<

 or 

>

 keys until 

[Clo,]

 appears, and then press 

/

 key.

If the controller's clock is not programmed (message

[ECLO]

) it is possible to adjust the time even 

when the functions are locked (message 

[LOC,]

 ). Under these conditions the clock adjustment is 

enabled and the other functions remain locked. After the clock is adjusted the adjustment function is 
locked again.