Full Gauge MT-516E Manual Download Page 1

DIGITAL TEMPERATURE CONTROL 

WITH CONFIGURABLE 2nd STAGE

MT516EV12-03T

-15358

5. INDICATIONS AND KEYS

1. DESCRIPTION

2. SAFETY RECOMMENDATIONS

3. APPLICATIONS

MT-516

is a temperature controller for cooling or heating applications. Equipped with a cyclic 

timer output, it can also be used as alarm output, with the option of an internal audible alarm (buzzer), or 
second cooling or heating stage. Another feature available is the turning off of the control functions, 

making  the

 

MT-516

e

 

operate  only  as  a  temperature  meter.  Through  an  intelligent  function 

blocking system, it prevents unauthorized personnel from changing the control settings.
Product conforming to UL Inc. (United States and Canada).

 
- Check the controller for correct assembling;
- Make sure that the power supply is off and that it is not turned on during the controller installation;
- Read the present manual before installing and using the controller;
- Use adequate Personal Protective Equipmenet (PPE);
- For application at sites subject to water spills, such as refrigerated cabinets, install the protecting vinyl 
supplied with the controller;
-  For  protection  under  more  critical  conditions,  we  recommend  the  Ecase  cover,  which  we  make 
available as an optional item (sold separately);
- The installation procedures should be performed by a qualified technician.

              

• Milk cooling tanks
• Refrigerated counters
• Air conditioning with automatic winter/summer system

evolution

 

 

MT-516

 

 

e

Ver

.12

Control Functions 

Shutdown

Functions 

Lockdown

Serial 

programming

Protection 

level

Cyclic 

Timer

IP 65

FRONT

Buzzer

MT-516

MT-516

(*)

Admissible variation in relation to the voltage rating.

(**)

This device can measure and control temperatures of up to 200° C when used in conjunction with a model SB59 silicon 

sensor cable (sold separately).

Note: 

Sensor cable length can be increased to up to 200 meters by the user by using a PP 2 x 24 AWG cable.

4. TECHNICAL SPECIFICATIONS

Control temperature

 

 -50 to 105ºC (-58 to 221°F)(**)

Power supply

MT-516E: 

115 or 230 Vac ±10%(*) (50/60 Hz) 

MT-516EL:

 12 or 24 Vac/dc +10%(*)  

Operating temperature

 

0 to 50 ºC / 32 to 122°F 

Operating humidity

10 to 90% RH (without condensation) 

Dimensions (mm)

76 x 34 x 77 mm (WxHxD)

Maximum output current

 OUT1: 

16(12)A / 240Vac 2HP

 OUT2: 

10A / 240Vac 1/4HP

Cutout dimensions (mm)

71 ± 0,5 x 29 ± 0,5 mm (see image V)

Set key

Quick access 

menu key (Flatec)

Functions lockdown indication LED

LED temperature unit

indicator

Upper key

Lower key

LED cooling indicator

LED heating indicator 

LED indicator (2nd stage output on)

MT-516

e

LED control functions shutdown 

indicator

Alarm

Image I: MT-516E - 115Vac

115 Vac

Image III: MT-516EL - 12Vac/dc

6. WIRING DIAGRAM

6.1. Identifications (see Images I to IV)

-

 

Image I:

 MT-516E , supplied at 115 Vac. 

-

 

Image II:

 MT-516E, supplied at 230 Vac. 

- Image III:

 MT-516EL, supplied at 12 Vac/dc. 

- Image IV:

 MT-516EL, supplied at 24Vac/dc.

Image

MT-516E 

 II: 

- 230 Vac

230 Vac

FONT

12Vac/dc

Image IV: MT-516EL - 24Vac/dc 

FONT

24Vac/dc

IMPORTANT

SCREWDRIVER SLOT 3/32''(2.4mm) FOR ADJUSTMENTS IN THE SIGNAL TERMINALS;
SCREWDRIVER PHILLIPS #1 FOR ADJUSTMENTS IN THE POWER TERMINALS;

THE USE OF APPROPRIATE TOOLS IS ESSENTIAL TO AVOID DAMAGE IN THE CONNECTION AT INSTRUMENT
TERMINALS:

6.2. 

Temperature sensor connection

- Connect the sensor wires to terminals ‘1 and 2’: the polarity is not relevant.
- Length of the sensor cables can be increased by user himself to up to 200 meters, using a PP 2x24
AWG cable.

S u r g e P r o t e c t i v e

Device (SPD)

(sold separately)

W i r i n g   d i a g r a m   f o r  

instalation  of  SPD  in 

magnectic contactor

A1 and A2 are the terminals 
of the contactor coil.

W i r i n g   d i a g r a m   f o r  

instalation  of  SPD  in  line 

with loads

For  direct  drive  take  in  to 
consideration  the  specified 
maximum current.

CONTROLLER

WIRING

TERMINALS

TEMPERATURE

SENSOR

WIRING

TERMINALS

POWER

GRID

LOAD

CONTROLLER

WIRING

TERMINALS

LOAD

TEMPERATURE

SENSOR

WIRING

TERMINALS

CONTROLLER

WIRING

TERMINALS

TEMPERATURE

SENSOR

WIRING

TERMINALS

LOAD

A1

A2

SPD

LOAD

SPD

LOAD

TEMPERATURE

SENSOR

CONTROLLER

WIRING

TERMINALS

WIRING

TERMINALS

NC

NC

NC

NC

}

POWER

GRID

}

POWER

GRID

}

POWER

GRID

}

NO NO

COMMON

COMMON

NO NO

COMMON

COMMON

NO NO

COMMON

COMMON

NO NO

COMMON

COMMON

E251415

Have this manual in the palm of 

your hand by

 FG Finder

 application.

Reviews: