background image

W

ARRANTY

 - FULL

 GAUGE CONTROLS

Products manufactured by Full Gauge Controls, as of May 2005, have a two (02) year 

warranty, as of the date of the consigned sale, as stated on the invoice. They are guaranteed 
against manufacturing defects that make them unsuitable or inadequate for their intended 
use.

EXCEPTIONS TO WARRANTY

The Warranty does not cover expenses incurred for freight and/or insurance when sending 

products  with  signs  of  defect  or  faulty  functioning  to  an  authorized  provider  of  technical 
support services. The following events are not covered either: natural wear and tear of parts; 
external damage caused by falls or inadequate packaging of products.

LOSS OF WARRANTY

Products will automatically lose its warranty in the following cases:
- The instructions for assembly and use found in the technical description and installation 

procedures in Standard IEC60364 are not obeyed;

-  The  product  is  submitted  to  conditions  beyond  the  limits  specified  in  its  technical 

description;

- The product is violated or repaired by any person not a member of the technical team of 

Full Gauge Controls;

- Damage has been caused by a fall, blow and/or impact, infiltration of water, overload 

and/or atmospheric discharge.

USE OF WARRANTY

To make use of the warranty, customers must send the properly packaged product to Full 

Gauge Controls together with the invoice or receipt for the corresponding purchase. As much 
information as possible in relation to the issue detected must be sent to facilitate analysis, 
testing and execution of the service.

These  procedures  and  any  maintenance  of  the  product  may  only  be  provided  by  Full 

Gauge Controls Technical Support services in the company's headquarters at Rua Júlio de 
Castilhos, 250 - CEP 92120-030 - Canoas - Rio Grande do Sul – Brasil

Rev. 03

ENVIRONMENTAL INFORMATION 

Packaging:

The materials used in the packaging of Full Gauge products are 100% recyclable. Try to 
perform disposal through specialized recyclers.

Product:

The  components  used  in  Full  Gauge  controllers  can  be  recycled  and  reused  if 
disassembled by specialized companies.

Disposal:

Do not incinerate or dispose the controllers that have reached the end of their service as 
household  garbage.  Observe  the  laws  in  your  area  regarding  disposal  of  electronic 
waste. If in doubt, please contact Full Gauge Controls.

Copyright 2016

13. ANNEXES - Reference Images

Image V

Image VI

Image VII

Y

X

CONTROLLER

LOCKS

PANEL

CONTROLLER

CONTROLLER

VINYL

PANEL

12. 

INTEGRATING CONTROLLERS, RS-485 SERIAL INTERFACE 

AND COMPUTER

A

B

MT-530

super

A

B

MT-530

super

A

A

B

B

A B

A

B

A

A

B

B

A B

A

A

B

B

A B

A

A

B

B

A B

*Connecting Block for Serial Communication

Used to connect more than one instrument to the Interface. The wire's connections must 
be made in agreement with the following rules: terminal 

A

 of the instrument connects to 

the terminal 

A

 of the c

, that must be connected with the terminal 

A

 of the 

Interface. Repeat the action for terminals 

B

 and  

  

, being  

 

 the cable shield.  

onnecting block

the terminal     of  onnecting block must be connected to the respective terminals     of 
each instrument.

c

*Sold Separately

CONV. 32 

or

CONV. 256

 Keep Sitrad updated in website:

 http://www.sitrad.com

®

Watch Sitrad installation video in: 

http://www.fullgauge.com/

videos/sitrad

9. DISPLAY SIGNALINGS

Sensor 1 disconnected or damaged.

Sensor 2 disconnected or damaged.

Sensor 3 disconnected or damaged.

Sensor 4 disconnected or damaged.

Functions lockdown activated.

Functions lockdown disabled.

Contact Full Gauge Controls.

Reconfigure the values of the functions.

[Err1]

[Err2]

[Err3]

10. GLOSSARY OF ACRONYMS

- °C: 

Temperature in Celsius degrees.

- °F:

 Temperature in Fahrenheit degrees.

- LOC:

 Blocked.

- No:

 No.

- OFF:

 Turned off/disabled.

- ON: 

Turned on, enabled.

- SET (as in "Setting")

 (setting or configuration).

- Vac:

 Electrical voltage (volts) of alternating current.

- Vdc:

 Electrical voltage (volts) of direct current.

- Yes:

 Yes.

[Err4]

[LOC,][On,,]

[LOC,][OFF,]

[eCAL]

[pppp]

Extended frame

It allows the installation of Evolution line 
controllers with sizes 76 x 34 x 77 mm in 
many differents situations, since it does 
not require precision in the notch of the 
instrument fitting panel. 
The  frame  integrates  two  switches  of 
10  Amperes  that  may  be  used  to 
actuate  interior  light,  air  curtain,  fan, 
and others.

Ecase protective cover

It is recommended for the Evolution line, avoids water from 
entering the back part of the instrument. It also protects the 
product when the installation site is washed.

11. OPTIONAL ITEMS - Sold Separately

ECASE PROTECTIVE COVER

CONTROLLER

EXTENDED FRAME

SWITCHES

 

 - version 2 or higher

EasyProg

It is an accessory that has as its main function to store the parameters of the controllers. At any time, you 
can load new parameters of a controller and unload them on a production line (of the same controller), 
for example. It has three types of connections to load or unload the parameters:

- Serial RS-485:

 It connects via RS-485 network to the controller (only 

for controllers that have RS-485). 

- USB:

 it can be connected to the computer via the USB port, using 

Sitrad's Recipe Editor.

-  Serial  TTL: 

The  controller  can  be  connected  directly  to 

EasyProg 

by the TTL Serial connection.

EASYPROG

Reviews: