8.4.1.  Adjustment of the parameters 

Access the function 

[,F01]

 by pressing simultaneously the keys

<

and

>

or by the facilitated menu. 

When 

[,F01]

 is displayed, press the key 

/

 (short touch). 

Use the keys 

<

 or 

>

 to enter with the access code 

[,123]

 and, when ready, press 

/

.           

Use the keys 

<

 or 

>

 to access the desired function. 

After selecting the function, press the key 

/

 (short touch), to view the value set for that function. Use 

the keys 

<

 or 

>

 to alter the value and press

/

 to memorize the value set and return to the function 

menu. 
To exit the menu and return to the normal operation (temperature indication), press 

/

 (long touch) until

 

[----]

 is displayed. 

NOTE  1:

 

If  function  blocking  is  active,  pressing  the  keys

<

or

>

,  the  controller  will  display

 

the 

message 

[LOC,]

 and parameters will not be allowed to be altered. 

NOTE 2: 

15 seconds after supplying the access code and/or after setting a parameter, with no touches 

in the buttons, the controller returns to the operation mode and the access code will have to be entered 
again in function F01.

8.4.2. Parameters table

8.4.3. Parameters description

 

F01 - Access codes:

The 

 is provided with two different access codes: 

[,123]

Allows changing the advanced parameters. 

[,231]

Allows selecting the temperature unit: Celsius or Fahrenheit.

 

F02 - Desired temperature (Setpoint): 

This is the reference value for temperature control, i.e., the desired temperature to maintain in the 
controlled environment, or the temperature at which the load supply output is turned off.
 

F03 - Indication shifting (Offset):

It allows the offsetting of any temperature deviations in view of the sensor replacement or alteration in 
the cable length.
 

F04 - Minimum setpoint allowed to the user:

Avoid selection, by mistake, of extremely low setpoint temperatures.

 

 F05 - Maximum setpoint allowed to the user: 

Avoid selection, by mistake, of extremely high setpoint temperatures.

 

F06 - Control differential (hysteresis):

This is the difference in temperature (hysteresis) between turning the refrigeration (or heating) ON and 
OFF.

Examples: 

- Refrigeration: 

One wants to control the temperature at 4.0 °C with a differential of 1.0 °C: the output 

will be turned off at 4.0 °C and turned on again at 5.0 °C (4.0 + 1.0). 

- Heating: 

One wants to control the temperature at 30.0 °C with a differential of 5.0 °C: the output will be 

turned off at 30.0 °C and turned on again at 25.0 °C (30.0 – 5.0). 

NOTE: 

Using very low hysteresis values will cause a high frequency at the on and off action of the relay, 

reducing its service life.

 

 

F07 - Operation mode:

Allows selecting the controller operation mode: 

[,,,0]

 Refrigeration 

[,,,1]

 Heating

F08 - Minimum output-on time:

This is the minimum time in which the load will remain on, i.e., the interval between the last start and the 
next stop.
 

F09 - Minimum output-off time:

This is the minimum time in which the load will remain off, i.e., the interval between the last stop and the 
next start. In the case of refrigeration, one relieves the discharge pressure, increasing the compressor 
service life.
 

F10 - Refrigeration time (defrost interval):

Corresponds  to  the  time  in  which  the  controller  will  operate  in  refrigeration. After  this  period,  the 
controller starts the defrost process.

F11 - Defrost time:

This is the defrost duration time. Within this period, the relay will remain off. After this period, the 
controller will return to the refrigerated state.

MT-512

e

 

2HP

F12 - Initial state when powering the instrument on:

When selecting the option

[,,,0]

 (Refrigeration), the controller starts the refrigeration. 

When selecting the option

[,,,1]

 (Defrost), the system will perform defrost when the controller is 

powered on. Duration of defrost will be according to parameter F11.

 

F13 - Locked temperature indication during defrost:

Select the acronym 

[No,,]

 for not locking the indication and 

[yes,]

 to lock it.

With the indication locked, this will only be released at the next refrigeration cycle after the temperature 
reaches again this ‘locked’ value or after 15 minutes in refrigeration (as a safety measure).
 

F14 - Instrument powering-on delay:

When the instrument is turned on, this may remain for a while with the control disabled, delaying the 
process start. Within this period, it works only as a temperature indicator. This delay may occur with the 
compressor or with defrost (when defrost is set at the start). 
The  goal  is  to  avoid  power  demand  peaks  upon  return  thereof  after  fault,  when  several  pieces  of 
equipment are connected in the same electric grid. The delays should be adjusted at different values for 
each piece of equipment. 

NOTE: 

After  the  end  of  delay,  the  ‘minimum  output-off  time’  count  is  started  (if  it  has  been  set  in 

parameter F09).

 

F15 - Additional time to the end of the first cycle:

It is used to increase the working time only of the first refrigeration cycle, increasing the efficiency.

 

F16 - Compressor situation with damaged sensor:

If the temperature sensor is undergoing short circuit, turned off or is off the measuring range, the 
compressor assumes the state set in this parameter: 

[,,,0]

 Compressor off. 

[,,,1]

 Compressor on. 

[,,,2]

 Cycling according to times defined in F17 and F18. 

NOTE: If it is in heating mode, and with some error, the output will be turned off.

 

F17 - Compressor-on time in the event of error:

It defines the minimum time during which the compressor will remain on, if the sensor is off or outside the 
measuring range.

F18 - Compressor-off time in the event of error:

It defines the minimum time during which the compressor will remain off, if the sensor is off or outside the 
measuring range.
 

F19 - Digital filter intensity:

This  filter  has  the  purpose  of  simulating  thermal  mass  increase  in  the  sensor,  thus  increasing  its 
response  time  (thermal  inertia).  The  greater  the  value  set  in  this  function,  the  greater  the  sensor 
response delay will be.

 

F20 - Function blocking time:

This functionality being active, the setpoint and the other parameters will be protected against undue 
alterations, with only the setpoint and the parameters being visualized. In order to block the functions, 
please refer to item 8.3.3. Function blocking.

 

F21 - Turning the control functions off:

Authorizes switching off the control functions (see item 8.3.4).

[no,,]

Disables the control functions shutdown.

[,,,1]

Enables activation/deactivation of the control functions only if the functions are unlocked.

[,,,2]

Enables activation/deactivation of the control functions even if the functions are locked.

[,,,3]

Enables activation/deactivation of the control functions only if the functions are unlocked.*

[,,,4]

Enables activation/deactivation of the control functions even if the functions are locked.*

* When F21 is configured as 3 or 4 and the control functions shutdown is activated, the controller will turn 
off the display, keeping only the indication       light on.
If any key is touched the display turns on by 5 seconds, turning off again until a new key is touched.

9. DISPLAY SIGNALINGS

10. GLOSSARY OF ACRONYMS

°C:

 Temperature in Celsius degrees. 

°F: 

Temperature in Fahrenheit degrees. 

Defr: 

Defrost. 

LOC: 

Blocked. 

No:

 No.

OFF: 

Turned off/disabled. 

ON:

 Turned on, enabled. 

Refr: 

Refrigeration. 

SET

 (as in "Setting") (setting or configuration). 

Vac:

 Electrical voltage (volts) of alternating current. 

Vdc:

 Electrical voltage (volts) of direct current. 

Yes: 

Yes.

Error in sensor: Sensor disconnected or damaged.

Control functions off.

Manual activation of the defrost process.

Manual activation of the cooling process.

Temper proof function.

Unlocking of functions.

Reconfigure the values of the functions.

[Er1,]

[OFF,]

[Defr][On,,]

[defr][Off,]

[LOC,][On,,]

[LOC,][OFF,]

[pppp]

Access codes 

Desired temperature (Setpoint)* 

Indication shifting (Offset)

Minimum setpoint allowed to the user

Maximum setpoint allowed to the user

Control differential (hysteresis) 

Operation mode

Minimum output-on time 

Minimum output-off time 

Refrigeration time (defrost interval)

Defrost time

Initial state when powering the instrument on 

Locked temperature indication during defrost

Instrument powering-on delay

Additional time to the end of the first cycle

Compressor situation with damaged sensor 

Compressor-on time in the event of error

Compressor-off time in the event of error

Digital filter intensity 

Function blocking time 

Turning the control functions off

[,F01]

[,F02]

[,F03]

[,F04]

[,F05]

[,F06]

[,F07]

[,F08]

[,F09]

[,F10]

[,F11]

[,F12]

[,F13]

[,F14]

[,F15]

[,F16]

[,f17]

[,f18]

[,F19]

[,F20]

[,F21]

Description

Fun

Min

Max Unit

-

200

5.0

200

200

20.0

1-heat.

999

999

999

999

1-defr.

yes.

240

240

2

999

999

9

60

4

-

°C

°C

°C

°C

ºC

-

sec

sec

min

min

-

-

min

min

-

min

min

-

sec

-

CELSIUS

-

-58

-9

-58

-58

1

no

no

1

no

no

no

no

0

1

1

no

no

no

0-cool.

0-cool.

-

392

9

392

392

36

1-heat.

999

999

999

999

1-defr

yes

240

240

2

999

999

9

60

4

-

°F

°F

°F

°F

°F

-

sec

sec

min

min

-

-

min

min

-

min

min

-

sec

-

FAHRENHEIT

Min

Max Unit

Standard

-

-50

-5.0

-50

-50

0.1

0-cool.

no

no

1

no

0-cool.

no

no

no

0

1

1

no

no

no

-

39

0

-58

167

1

20

20

240

30

no

no

no

0

15

15

no

no

no

0-cool.

0-cool.

-

4

0

-50

75

1.0

0-cool.

20

20

240

30

0-cool.

no

no

no

0

15

15

no

no

no

Standard

Legend: 

[yes,]

= yes

              

[no,,]

= no

*The minimum and maximum values depend on
the values configured in 

[,F04]

 and 

[,F05]

.

 

 

Summary of Contents for MT-512E 2HP

Page 1: ...ockdown indication LED 50 to 105 C 58 to 221 F 0 1 C 10 to 100 C and 1 C at the rest of the range 115 Vac Image III MT 512EL 2HP 12Vac dc Power supply MT 512E 2HP 115 or 230 Vac 50 60 Hz 10 MT 512EL 2HP 12 or 24 Vdc or Vac 10 Maximum load current 16 A for resistive type loads and 12 A for inductive type loads Maximum load power 2HP Operating temperature 0 to 50 C 32 to 122 F Operating humidity 10 ...

Page 2: ...ated deactivatedbypressingthekey for4seconds MT 512e 2HP 8 3 3 Function blocking The activation of function blocking feature allows safety against undue alterations of the Setpoint and of the other parameters In this condition when trying to alter the values the message LOC will be displayed However theparameterscanstillbeseen In order to perform the function blocking the parameter F20 Time for fu...

Page 3: ...quipment are connected in the same electric grid The delays should be adjusted at different values for eachpieceofequipment NOTE After the end of delay the minimum output off time count is started if it has been set in parameterF09 F15 Additionaltimetotheendofthefirstcycle Itisusedtoincreasetheworkingtimeonlyofthefirstrefrigerationcycle increasingtheefficiency F16 Compressorsituationwithdamagedsen...

Page 4: ...ols Damage has been caused by a fall blow and or impact infiltration of water overload and or atmospheric discharge USE OF WARRANTY To make use of the warranty customers must send the properly packaged product to Full Gauge Controls together with the invoice or receipt for the corresponding purchase As much information as possible in relation to the issue detected must be sent to facilitate analys...

Reviews: