Full Gauge Controls microsol II plus User Manual Download Page 1

DIFFERENTIAL TEMPERATURE

 CONTROLLER FOR SOLAR HEATING 

WITH TWO SOLAR BACKING

Ver.06

MICROSOL II plus

1 - DESCRIPTION

Differential temperature controller for automation of solar heating systems, 

MICROSOL II plus

 

becomes  simple  the  management  of  the  temperature  of  the  water  in  the  thermal  reservoirs  and 
swimming pools, use the solar energy better. It has functions that prevent the water overheating and 
freezing in the tubings. 
It acts in the command of the water circulation pump through the differential of temperature between the 
solar collectors and the thermal reservoir or swimming pool. It makes use of two solar backing outputs, 
that can be electric, gas, diesel or also to program the filtering of the swimming pool. 

In addition, it features a real 

time scheduler that allows programming a weekly schedule with up to four daily events and a clock with 
internal battery to guarantee its synchronism, even in the energy lack, for a few months.
It is a dedicated instrument that has all its parameters of configuration protected by access code. 

2 - APPLICATION

• Solar heating pumped systems

 

Output AUX2 can 

also be used to program pool filtration or as thermostat for water circulation in the keg so the hot water 
takes less time to reach the consumption point, thus wasting less water.

 

3 - 

- Power supply: 

Microsol II plus:  115 or 230Vac ± 10% (50/60Hz) 

                           

Microsol II L plus:  12 or 24Vac/dc

- Control temperature:

 Sensor 1: -50 to 200°C / -58 to 392°F

Sensors 2 and 3: -50 to 105°C / -58 to 221°F

  

- Resolution:

0.1°C between -10 and 100°C and 1°C in the rest of the range
1°F in all range

- Dimensions: 

71 x 28 x 71mm

- Operating temperature: 

0 to 50°C / 32 to 122°F

- Operating humidity: 

10 to 90% RH (without condensation)

- Sensors:

 

MICROSOL II plus 

has three sensors: 

Sensor 1 - Panels (or solar collector) - Metal capsule - Silicone
Sensor 2 - Pool (or thermal reservoir) - Plastic capsule - PVC
Sensor 3 - Sensor for control of solar backings - Plastic capsule - PVC

- Control outputs:

PUMP -

 

Water pump or solenoid - 5(3)A / 250Vac 1/8HP

It has 2 outputs for solar backing (support system)
AUX1 - Solar backing 1 - 5(3)A / 250Vac 1/8HP
AUX2 - Solar backing 2 - 5(3)A / 250Vac 1/8HP

What are solar backing (or support systems)? hey work as backup for the solar heating system on rainy 
and cold days. Usually they are gas burners, electric heaters, or heat exchangers (heat pump). If the 
solar heating is not sufficient to heat the water (either from the thermal reservoir and the pool), the  solar 
backings are activated to warm it. Remembering that

 

the SENSOR 3 is responsible for driving the solar 

backings (support systems). This controller is equipped with an internal circuit, which assures clock 
synchronization in the event of power outage for a period of 24 hours. However, it should initially be 
charged for a period of 10 hours or whenever the equipment remains off for a period of over 24 hours.

TECHNICAL SPECIFICATIONS

4 - ADVANCED SETTINGS

 - How to adjust the temperature of the swimming pool 

or the reservoir?

Hold the             key for 5 seconds until it display                 . This parameter enable to set the desired 
temperature of the swimming pool or the reservoir.

4.1 - To access the options menu

Press             and             simultaneously for two seconds until it appears               , then releasing it. When 
appears           press        (tap) and enter the code (123) through keys       and       . To confirm,
press the key         . Through the keys        and        access the other functions and proceed in the same 
manner to adjust them. To leave the menu and return to normal operations, press       (long hit) until            
         appears.

4.2 - Options

Access code entry
Advanced configuration functions
Events planner operating mode 
Scheduling in the events planner 
Adjustment of the clock and the day of the week

IMPORTANT

SET

SET

SET

4.2.1 - Settings parameters

CELSIUS

Fun

FAHRENHEIT

Indication of the preferential temperature

Differential for turning on the water circulation pump

Differential for turning off the water circulation pump

Minimum temperature at S1 to switch on the pump

Pump switch on delay

Negative differential (S1-S2) to switch on the pump to 

dissipate heat

Minimum temperature at S2 to allow activating heat 

dissipation

Antifreeze S1 to switch on the pump

Antifreeze hysteresis

Minimum antifreeze time

Overheating temperature S1 to switch off the pump

Overheating hysteresis to switch on the pump 

Overheating temperature S2 to switch off the pump

Overheating hysteresis to switch on the pump (S2)

Solar backing 1 operating mode

0

1.0

1.0

-50.0

0

-40.0

0.0

-18

0.1

0

0.0

0.1

0.0

0.1

0

-

°C

°C

°C

sec.

  

°C

°C

°C

°C

sec.

°C

°C

°C

°C

-

3

40.0

40.0

200

999

0.0

105

10.0

20.0

999

200

20.0

105

20.0

1

0

1

1

-58

0

-72

32

-1

1

0

32

1

32

1

0

3

72

72

392

999

0

221

50

36

999

392

36

221

36

1

-

°F

°F

°F

sec.

  

°F

°F

°F

°F

sec.

°F

°F

°F

°F

-

Solar backing 1 temperature setpoint

Solar backing 1 activation hysteresis

Minimum value for solar backing 1 temperature setpoint

Maximum value for solar backing 1 temperature setpoint

Solar backing 1 manual activation time

Solar backing 2 operating mode

Solar backing 2 temperature setpoint

Solar backing 2 activation hysteresis

Minimum value for solar backing 2 temperature setpoint

Maximum value for solar backing 2 temperature setpoint

Solar backing 2 manual activation time

Cyclic timer on time

Cyclic timer off time

Event schedule linking mode

Minimum S1 temperature alarm

Maximum S1 temperature alarm

S1 temperature indication offset

S2 temperature indication offset

S3 temperature indication offset

Water pump activation mode

RS-485 network address

-50.0

0.1

-50.0

-50.0

0

0

-50.0

0.1

-50.0

-50.0

0

1

1

0

-50.0

-50.0

-5.0

-5.0

-5.0

1

95

1

-58

221

0

1

86

1

-58

221

0

1

1

0

-58

392

0

0

0

1

221

36

221

221

999

8

221

36

221

221

999

999

999

3

392

392

9

9

10

247

-58

1

-58

-58

0

0

-58

1

-58

-58

0

1

1

0

-58

-58

-9

-9

-9

1

35.0

1.0

-50.0

105

0

1

30.0

1.0

-50.0

105

0

1

1

0

-50.0

200

0.0

0.0

0.0

1

°C

°C

°C

°C

min.

-

°C

°C

°C

°C

min.

min.

min.

-

°C

°C

°C

°C

°C

-

-

105

20.0

105

105

999

8

105

20

105

105

999

999

999

3

200

200

5.0

5.0

5.1

247

°F

°F

°F

°F

min.

-

°F

°F

°F

°F

min.

min.

min.

-

°F

°F

°F

°F

°F

-

-

4.2.1.1 - Parameters description

Indication of the preferential temperature

It allows the preferential temperature indication to be configured. You may choose between:

Shows the panel temperature (solar collector);
Shows the swimming pool or thermal tank (bath) temperature;
Shows the solar backings temperature (support systems);
Shows the difference (°C) between the solar panel (sensor 1) and the swimming pool or 
thermal tank (sensor 2).

Differential for turning on the water circulation pump

Allows  configuring  the  temperature  difference  in  degrees  between  sensor  1  and  sensor  2  for 

MICROSOL II plus

 to turn on the water circulation pump.

Differential for turning off the water circulation pump

Allows  configuring  the  temperature  difference  in  degrees  between  sensor  1  and  sensor  2  for 

MICROSOL II plus

  to turn off the water circulation pump.

Exemple:
F02= 8.0
F03= 4.0
When sensor 1 (panel) is at 35°C and sensor 2 (swimming pool or tank) is at 23°C, the difference is 12ºC, 
thus the circulation pump must be on (35-23 = 12, more than 8). With time the difference between sensor 1 
and sensor 2 tends to decrease. Thus when the difference between sensor 1 and sensor 2 reaches 4ºC 
(function F03), the circulation pump will be turned off (35-31 = 4).  
The thermostat panel has an indicator LED "

PUMP

" (upper left). When the LED is on, the pump is on. 

When the LED "

PUMP

" is off, the pump is off.

Minimum temperature at S1 to switch on the pump

Prevents  the  pump  from  being  turned  on  when  the  temperature  of  the  panel  (collector)  is  below  the 
required temperature, thus preventing warm or cold water from circulating through the system, which 
would cause higher power consumption. 

 

 Pump switch on delay

This function protects the pump from burning out in case of power fault (counts the time in seconds). 
Example: When there is a power fault and the power is restored immediately after, 

MICROSOL II plus

 

will first count the time programmed in function F05 before activating the circulation pump. This function 
also helps to reduce the voltage surge that can happen in the protection devices (circuit breakers) when 
activating many loads at the same time.

To deactivate this function, just decrement the value until the 

message           is displayed. 

SET

Description

Min Max Unit Standard

Standard

Min Max Unit

1

8.0

4.0

-50.0

0

0.0

105

8.0

5.0

0

90.0

1

105

1.0

0

1

14

7

-58

0

0

221

46

9

0

194

1

221

1

0

MCSOL2V06-01T

-15124

Negative differential (S1-S2) to switch on the pump to dissipate heat

If the temperature in the tank or swimming pool is too high, 

MICROSOL II plus

 turns the circulation 

pump on (even if the water in the panels is cool) to cool the consumption water a little (swimming pool or 
thermal tank).

increase

Minimum temperature at S2 to allow activating heat dissipation

As a safety measure, the user can use this function to configure the minimum temperature at sensor 2 to 
dissipate heat. 

increase

To deactivate this function, just 

 the value until the message            is displayed. 

To deactivate this function, just 

 the value until the message            is displayed. 

Antifreeze S1 to switch on the pump

The technician uses this function to configure a temperature value to prevent the panels from freezing 
(in cold regions). When sensor 1 reaches the programmed temperature, the circulation pump is turned 
on.  To deactivate this function, just decrement the value until the message            is displayed. 

Antifreeze hysteresis

The temperature difference in sensor 1 (panel) for the antifreeze to be turned off. 
Example:
F08= 5.0
F09= 1.0 difWhen sensor 1 measures 5°C (function F08), it will interpret that the temperature is dangerous 
and can freeze the panels. It activates the circulation pump so that a little warm water from the pool or tank 
passes through the panels. Thus, after raising 1°C (function F09), the temperature reaches 6ºC and the 
pump is turned off (5+1=6).

Minimum antifreeze time

This minimum pump on time is a safety measure to ensure that the water can pass through all the panels. 
This function is frequently used in large installations due to the number of panels required. 

Summary of Contents for microsol II plus

Page 1: ...ctivation time Solar backing 2 operating mode Solar backing 2 temperature setpoint Solar backing 2 activation hysteresis Minimum value for solar backing 2 temperature setpoint Maximum value for solar backing 2 temperature setpoint Solar backing 2 manual activation time Cyclic timer on time Cyclic timer off time Event schedule linking mode Minimum S1 temperature alarm Maximum S1 temperature alarm S...

Page 2: ...he key successively until the message is displayed Press to confirm After sensor 3 is disabled solar backing 1 and 2 will be controlled by sensor 2 tank swimmingpool If the activation of the water pump is linked to sensor 3 and this sensor is disabled the controller will automaticallyunlinkthem SET RS 485networkaddress Equipment snetworkaddressforcommunicatingwithSITRAD software Note it is not all...

Page 3: ...between the temperature views for sensor 1 sensor 2 sensor 3 or temperature difference betweensensors1and2 differentialtemperature press tilthedesiredtemperatureisdisplayed Sensor1temperature Sensor2temperature Sensor3temperature Differentialtemperature S1 S2 Theselectedtemperaturewillbedisplayedfor15secondsandthenthedefaultindicationreturns asper parametersetting 6 2 Visualize the current time Qu...

Page 4: ...ng for setting of the instrument in panel 29 mm ENVIRONMENTALINFORMATION Package The packages material are 100 recyclable Just dispose it through specialized recyclers Products The electro components of Full Gauge controllers can be recycled or reused if it is disassembledforspecializedcompanies Disposal Do not burn or throw in domestic garbage the controllers which have reached the end of life Ob...

Reviews: