background image

5.5 TIME AND DAY SETTINGS

In order to access the Time and Day menu, just give a short touch on the      key. Through 
the     or      keys it is possible to navigate among the parameters to view them. In order to 
edit them press the 

SET

 key and through the      or      keys update its value. The values 

will  flash  in  adjustment  mode.  Confirm  the  time  value  with  the 

  key.  After  the 

SET

confirmation, adjust the day and confirm with the 

 key again to exit the adjustment 

SET

mode.

Clock - Time settings.

   

   
   Day - Day of the week settings. 

Adjustable from 1 (Sunday) to 7 (Saturday).

NOTICE:
The controller has an internal auxiliary power supply to maintain the clock during 
power  failure  for  at  least  72  hours.  If  the  controller  remains  turned  off  for  a 
prolonged period of time, it will display the message 

[ECLO]

, indicating that the 

clock is deprogrammed. In this situation the controller's date and time must be set, 
keeping it energized for 10 hours so that the auxiliary source is fully recharged.

Obs.:

  In  the  parameter  menu,  to  leave  and  return  to  normal  operation  (preferential 

indication of temperature and time) maintain the 

SET

 key pressed (long touch) until the 

message 

[----]

  appears.  When  the  Fahrenheit  temperature  scale  is  selected,  the 

clock acquires the 12h standard, and the AM and PM icons are used for time indication. In 
this scale, the Time and Day messages of the parameter description are replaced by Time 
and Day in the controller display.

Obs.:

 In the support mode settings, the controller takes on the new mode 5 seconds after 

its selection. This also is the time necessary for the parameter to be stored in its memory. 
The manual mode is used when one wishes to occasionally heat the thermal reservoir out 
of the schedules expected in the event schedule. In manual mode, the support outlet 
remains  associated  to  the  T3  sensor  temperature  through  the  Support  Heating 
Temperature (parameter 

[TEMP]

). In this mode, the controller allows the support outlet 

to be turned on during the period programmed in parameter 

[,F19]

.

5.4.1 VACATION MODE

To enable/disable the Vacation mode, the     key must be held for 4 seconds.
                                         
                                                  OFF: vacation mode enabled.

When enabled:

* The event schedule is ignored, the support outlet is turned off, resulting in energy 
consumption reduction.
* Performs the reservoir cooling as programmed in 

[,F10]

 - temperature on T3 

sensor to turn off cooling in Vacation mode.

The Vacation mode is used to turn off support and allow the reservoir to be cooled through the 
solar collector when its temperature is lower than the reservoir's, i.e.: during the night. In 
periods  with  low  or  no  consumption  of  hot  water  and  high  solar  intensity,  for  example, 
vacation, extended holidays or period away from the residence, the reservoir will reach its 
higher limit of temperature and the system of solar heating will be subject to high thermal load.

5.6 EVENT SCHEDULE SETTINGS

4 seconds

off

AUX

If it is not necessary to use all 4 events, you should set these in the turned off state, by just 
increasing the final time until 

[,OFF]

appears. It is possible to set an event that begins in 

one  day  and  finishes  in  another. To  do  so  you  should  raise  the  final  event  time  until

 

[,CRo]

appears and set on the following day the initial event with time on 

[00:00]

.

Obs.:

 In Support mode settings, the controller takes on the new mode 5 seconds after its 

selection. This also is the time necessary for the parameter to be stored in its memory.

To set the event schedule associated to the support outlet, you should hold the       key for 
4 seconds.
The schedule allows setting up to 4 events for each day of the week, as the programming 
performed in parameter 

[,F20]

 - support event schedule operation mode. Each event is 

comprised by a final and initial schedule. 
The event schedule gets factory settings in mode 

[,1t7]

, same events for each day of 

the week, and the schedules are defined as follows:

am pm

Hold for 

4 sec.

2 seconds

am pm

am pm

 

SET

Long touch

Preferential 

indication

Weekly

programming

Sunday

Monday

Tuesday

Wednesday

Thursday

Friday

 Saturday

 

SET

Short touch

 

SET

Long touch

According  to  the  set  operation  mode,  the  following  programming  possibilities  may  be 
presented:

Programmed case 

[,F20]

 = 

[,1B1]

Programmed case 

[,F20]

 = 

[,2T6]

 

SET

Adjustment

Short touch

 

SET

Short touch

 

SET

Short touch

 

SET

Short touch

am pm

Hold for 

4 sec.

2 seconds

 

SET

Long touch

Preferential 

indication

Weekday 

Programming 

am pm

am pm

Sunday

Weekdays

 Saturday

 

SET

Short touch

 

SET

Long touch

 

SET

Short touch

 

SET

Short touch

 

SET

Short touch

 

SET

Short touch

Programmed case 

[,F20]

 = 

[,1T7]

am pm

Hold for 

4 sec.

2 seconds

 

SET

Long touch

Preferential 

indication

Daily 

programming

 

SET

Short touch

 

SET

Short touch

 

SET

Short touch

 

SET

Short touch

5.7 VIEW OTHER TEMPERATURES

To switch the temperature display of sensor T1, sensor T2, sensor T3 or the differential 
sensor  (T1-T2)  give  short  touches  on  the            key    until  the  desired  temperature  is 
displayed. In the upper display numbers the temperature measure is presented and in the 
lower display numbers, the sensor description.
The  selected  temperature  will  be  displayed  during  10  seconds.  After,  which  the 
preferential  indication  is  again  displayed,  as  set  in  parameter 

[,F01]

  –  Preferential 

Indication.

5.8 FUNCTION BLOCK

For security reasons and in order to avoid unauthorized people changing the controller 
settings, there is the function block resource. With that setting activated, the parameters 
cannot be changed, but they can be displayed, however. In the block condition, upon trying 
to change the value of a parameter the message "

[,LOC][,,ON]

no display" will be 

displayed.
To  enable/disable  the  function  block  you  should  hold  the          key  for  the  time  set  in 
parameter 

[,F25]

 – Time for function block. The      icon indicates the block state to the 

user, in case it is accessed, it indicates that the function block is active.

HINT: 

with active function block one avoids that children, visitors or curious people change 

the operation mode or the controller parameters. When some change is needed, just hold 
the       key to enable/disable this resource.

6. ADVANCED OPERATIONS FOR THE INSTALLER (TECHNICAL USE)
6.1 CONTROLLER PARAMETERS CHANGE

Access the settings menu holding the 

SET 

key for 4 seconds until 

[FuNc]

 appears. 

After that 

[Code] 

will appear and then press once again the 

SET

 key, short touch. Use 

the      or      keys to enter the access code value, 123, and when ready press the 

SET

 key 

once again (short touch).
Use the      or      keys to select the desired function. With a short touch to the 

SET

 key it’s 

possible to edit its value. Use the     or     keys to change the value, and when ready give a 
short touch on the 

SET

 key to memorize the set value and return to the function menu.

Initial time for the

1st event 

End time for the

1st event

1 second

1 second

1 second

Adjustment

Adjustment

Adjustment

Adjustment

Adjustment

Adjustment

Adjustment

Adjustment

Adjustment

Adjustment

Adjustment

Initial time for the

2st event 

End time for the

2st event

Initial time for the

4st event 

End time for the

4st event

Initial time for the

3st event 

End time for the

3st event

SET

SET