5.5 TIME AND DAY SETTINGS
In order to access the Time and Day menu, just give a short touch on the key. Through
the or keys it is possible to navigate among the parameters to view them. In order to
edit them press the
SET
key and through the or keys update its value. The values
will flash in adjustment mode. Confirm the time value with the
key. After the
SET
confirmation, adjust the day and confirm with the
key again to exit the adjustment
SET
mode.
Clock - Time settings.
Day - Day of the week settings.
Adjustable from 1 (Sunday) to 7 (Saturday).
NOTICE:
The controller has an internal auxiliary power supply to maintain the clock during
power failure for at least 72 hours. If the controller remains turned off for a
prolonged period of time, it will display the message
[ECLO]
, indicating that the
clock is deprogrammed. In this situation the controller's date and time must be set,
keeping it energized for 10 hours so that the auxiliary source is fully recharged.
Obs.:
In the parameter menu, to leave and return to normal operation (preferential
indication of temperature and time) maintain the
SET
key pressed (long touch) until the
message
[----]
appears. When the Fahrenheit temperature scale is selected, the
clock acquires the 12h standard, and the AM and PM icons are used for time indication. In
this scale, the Time and Day messages of the parameter description are replaced by Time
and Day in the controller display.
Obs.:
In the support mode settings, the controller takes on the new mode 5 seconds after
its selection. This also is the time necessary for the parameter to be stored in its memory.
The manual mode is used when one wishes to occasionally heat the thermal reservoir out
of the schedules expected in the event schedule. In manual mode, the support outlet
remains associated to the T3 sensor temperature through the Support Heating
Temperature (parameter
[TEMP]
). In this mode, the controller allows the support outlet
to be turned on during the period programmed in parameter
[,F19]
.
5.4.1 VACATION MODE
To enable/disable the Vacation mode, the key must be held for 4 seconds.
OFF: vacation mode enabled.
When enabled:
* The event schedule is ignored, the support outlet is turned off, resulting in energy
consumption reduction.
* Performs the reservoir cooling as programmed in
[,F10]
- temperature on T3
sensor to turn off cooling in Vacation mode.
The Vacation mode is used to turn off support and allow the reservoir to be cooled through the
solar collector when its temperature is lower than the reservoir's, i.e.: during the night. In
periods with low or no consumption of hot water and high solar intensity, for example,
vacation, extended holidays or period away from the residence, the reservoir will reach its
higher limit of temperature and the system of solar heating will be subject to high thermal load.
5.6 EVENT SCHEDULE SETTINGS
4 seconds
off
AUX
If it is not necessary to use all 4 events, you should set these in the turned off state, by just
increasing the final time until
[,OFF]
appears. It is possible to set an event that begins in
one day and finishes in another. To do so you should raise the final event time until
[,CRo]
appears and set on the following day the initial event with time on
[00:00]
.
Obs.:
In Support mode settings, the controller takes on the new mode 5 seconds after its
selection. This also is the time necessary for the parameter to be stored in its memory.
To set the event schedule associated to the support outlet, you should hold the key for
4 seconds.
The schedule allows setting up to 4 events for each day of the week, as the programming
performed in parameter
[,F20]
- support event schedule operation mode. Each event is
comprised by a final and initial schedule.
The event schedule gets factory settings in mode
[,1t7]
, same events for each day of
the week, and the schedules are defined as follows:
am pm
Hold for
4 sec.
2 seconds
am pm
am pm
SET
Long touch
Preferential
indication
Weekly
programming
Sunday
Monday
Tuesday
Wednesday
Thursday
Friday
Saturday
SET
Short touch
SET
Long touch
According to the set operation mode, the following programming possibilities may be
presented:
Programmed case
[,F20]
=
[,1B1]
Programmed case
[,F20]
=
[,2T6]
SET
Adjustment
Short touch
SET
Short touch
SET
Short touch
SET
Short touch
am pm
Hold for
4 sec.
2 seconds
SET
Long touch
Preferential
indication
Weekday
Programming
am pm
am pm
Sunday
Weekdays
Saturday
SET
Short touch
SET
Long touch
SET
Short touch
SET
Short touch
SET
Short touch
SET
Short touch
Programmed case
[,F20]
=
[,1T7]
am pm
Hold for
4 sec.
2 seconds
SET
Long touch
Preferential
indication
Daily
programming
SET
Short touch
SET
Short touch
SET
Short touch
SET
Short touch
5.7 VIEW OTHER TEMPERATURES
To switch the temperature display of sensor T1, sensor T2, sensor T3 or the differential
sensor (T1-T2) give short touches on the key until the desired temperature is
displayed. In the upper display numbers the temperature measure is presented and in the
lower display numbers, the sensor description.
The selected temperature will be displayed during 10 seconds. After, which the
preferential indication is again displayed, as set in parameter
[,F01]
– Preferential
Indication.
5.8 FUNCTION BLOCK
For security reasons and in order to avoid unauthorized people changing the controller
settings, there is the function block resource. With that setting activated, the parameters
cannot be changed, but they can be displayed, however. In the block condition, upon trying
to change the value of a parameter the message "
[,LOC][,,ON]
no display" will be
displayed.
To enable/disable the function block you should hold the key for the time set in
parameter
[,F25]
– Time for function block. The icon indicates the block state to the
user, in case it is accessed, it indicates that the function block is active.
HINT:
with active function block one avoids that children, visitors or curious people change
the operation mode or the controller parameters. When some change is needed, just hold
the key to enable/disable this resource.
6. ADVANCED OPERATIONS FOR THE INSTALLER (TECHNICAL USE)
6.1 CONTROLLER PARAMETERS CHANGE
Access the settings menu holding the
SET
key for 4 seconds until
[FuNc]
appears.
After that
[Code]
will appear and then press once again the
SET
key, short touch. Use
the or keys to enter the access code value, 123, and when ready press the
SET
key
once again (short touch).
Use the or keys to select the desired function. With a short touch to the
SET
key it’s
possible to edit its value. Use the or keys to change the value, and when ready give a
short touch on the
SET
key to memorize the set value and return to the function menu.
Initial time for the
1st event
End time for the
1st event
1 second
1 second
1 second
Adjustment
Adjustment
Adjustment
Adjustment
Adjustment
Adjustment
Adjustment
Adjustment
Adjustment
Adjustment
Adjustment
Initial time for the
2st event
End time for the
2st event
Initial time for the
4st event
End time for the
4st event
Initial time for the
3st event
End time for the
3st event
SET