EM DESENVOL
VIMENT
O
A
A
B
B
A B
Multi-FG
REMOTE INTERFACE FOR
DIGITAL CONTROLLERS
1. DESCRIPTION
2. APPLICATIONS
Multi-FG
is an interface intended for controllers with RS485 connection and compatible protocol,
and it can be used with up to 32 instruments.
It enables viewing temperatures and controller status, changing the value of function parameters, and
sending commands. The instruments to be viewed may be changed automatically or manually.
Multi-FG
protocol.
Interface for controllers compatible with
evolution
Multi-FG
Ver
.01
Multi-FG
Multi-FG
Functions
lockdown
Protection
level
Defrost
manual
IP 65
FRONT
6. FIRST STEPS
6.1 Electric connection and RS485 Network
After all connections are ready (sensors, relays, valve, and RS-485 networks) the configuration must be carried out with one controller at a time. To do this, power up only the first controller to be configured. When
has no instruments registered in the scan list the message
[None]
blinks on the main screen. Follow the next steps in this chapter to add the address of the controller in
.
Multi-FG
Multi-FG
B A
6.2 Entering the access code
Access the main menu by pressing the keys
>
and
<
, simultaneously. Menu
[Code]
will be displayed upon releasing the keys. Enter the
code 123
to gain full access to the other menus.
6.3 Adding a new controller
Follow the steps below to add new network controllers:
1)
With the access code previously entered (according to item 6.2), use the keys
>
or
<
to access the menu
[ADD,]
and then press
/
.
The value to be sent to the controller in its new address is shown in the display. Adjust the value using the keys
>
and
<
and press
/
to confirm.
- The message
[done]
is displayed if the address is successfully configured.
- The message
[used]
is displayed if the address is already on the list.
- The message
[Ecnn]
is displayed if there is an error in the connection.
NOTE:
In case of connection error, check the terminals for correct connection and tightening and the wires for ruptures. Try the same command again after checking.
4. INDICATIONS AND KEYS
Increase key
Decrease key
Set key
Quick Access
Menu Key (Flatec)
Address switching indicator led
Compressor output indicator led
Defrost indicator led
Fan indicator led
Economy mode indicator led
3. TECHNICAL SPECIFICATIONS
Power supply
Dimensions
76 x 34 x 77 mm (WxHxD)
Dimensions of the clipping for
fixing of the instrument
71 ± 0,5 x 29 ± 0,5 mm (see item 5)
Multi-FG:
115 or 230 Vac ±10%(50/60 Hz)
5. INSTALLATION - ELECTRICAL CONNECTIONS AND PANEL
Panel (Front View)
Panel
(Side View)
Dimension of the clipping
for setting of the
instrument in panel
71
mm
± 0,5
29
mm
± 0,5
1
5 6 7 8
2 3 4
9
POWER
SUPPLY
10 11 12 13 14 15 16 17
115 Vac
Connection 115 Vac
A
B
Connection 230 Vac
1
5 6 7 8
2 3 4
9
POWER
SUPPLY
10 11 12 13 14 15
230 Vac
16 17
A
B
FOR INSTALLATIONS WHERE A SEALING IS REQUIRED TO
AVOID LIQUID CONTACT, THE CUT FOR THE CONTROLLER
MUST BE OF 70,5X29mm MAXIMUM. THE SIDE LOCKS MUST BE
FIXED SO IT PRESSES THE RUBBER SEALING AVOIDING
INFILTRATION BETWEEN THE CUT AND THE CONTROLLER.
ATTENTION
IMPORTANT
THE USE OF APPROPRIATE TOOLS IS ESSENTIAL TO AVOID
DAMAGE IN THE CONNECTION AT INSTRUMENT TERMINALS:
SCREWDRIVER SLOT 3/32''(2.4mm) FOR ADJUSTMENTS IN
THE SIGNAL TERMINALS;
SCREWDRIVER PHILLIPS #1 FOR ADJUSTMENTS IN THE
POWER TERMINALS;
Multi-FG
Sitrad
VEE
Power
MULTI-FG
2 |
multi-FG (B)
1 |
multi-FG (A)
SITRAD
11 |
SITRAD (A)
12 |
SITRAD (B)
RELAYS
13-14 |
fans
15-16 |
compressor
17-18 |
defrost
Line
SENS. PRESS.
3 |
4~20mA (green)
4 |
12Vdc (brown)
|
Power Supply
12Vdc - 1.3A
vx-
950
plus
SENS. TEMP. / DIG. IN
9-10 |
sens. ambient temp.
8-9 |
sens. evap. temp.
6-7 |
sens. suction temp.
5-6 |
digital input (door)
A B
A
A
B
B
A B
A B
Multi-FG
Sitrad
VEE
Power
MULTI-FG
2 |
multi-FG (B)
1 |
multi-FG (A)
SITRAD
11 |
SITRAD (A)
12 |
SITRAD (B)
RELAYS
13-14 |
fans
15-16 |
compressor
17-18 |
defrost
Line
SENS. PRESS.
3 |
4~20mA (green)
4 |
12Vdc (brown)
|
Power Supply
12Vdc - 1.3A
vx-
950
plus
SENS. TEMP. / DIG. IN
9-10 |
sens. ambient temp.
8-9 |
sens. evap. temp.
6-7 |
sens. suction temp.
5-6 |
digital input (door)
Multi-FG
Sitrad
VEE
Power
MULTI-FG
2 |
multi-FG (B)
1 |
multi-FG (A)
SITRAD
11 |
SITRAD (A)
12 |
SITRAD (B)
RELAYS
13-14 |
fans
15-16 |
compressor
17-18 |
defrost
Line
SENS. PRESS.
3 |
4~20mA (green)
4 |
12Vdc (brown)
|
Power Supply
12Vdc - 1.3A
vx-
950
plus
SENS. TEMP. / DIG. IN
9-10 |
sens. ambient temp.
8-9 |
sens. evap. temp.
6-7 |
sens. suction temp.
5-6 |
digital input (door)
A
A
B
B
A B
A B
12Vdc
1.3A
Powered down controller
LEGEND
12Vdc
1.3A
12Vdc
1.3A
Multi-FG
115/230 Vac MAINS
Control temperature
0 to 50°C / 32 to 122°F
- Use a 120 Ω termination resistor in
terminals A and B of the last network
connection block.
- Maximum cable length is 100 meters.
Full Gauge Controls recommends:
120
Ω
WARNING
ACCESSORIES:
Only use original Full Gauge Controls accessories.
If you have any questions, please contact technical support.
AUTHORIZED SERVICE:
The installation or maintenance of the product must be performed by qualified professionals only;
BEFORE INSTALLING THE CONTROLLER, WE RECOMMEND READING THROUGH THE
ENTIRE INSTRUCTION MANUAL IN ORDER TO AVOID POSSIBLE DAMAGE TO THE
PRODUCT.
PRECAUTIONS WHEN INSTALLING THE PRODUCT:
Before performing any procedure on this instrument, disconnect it from the mains;
Ensure that the instrument has adequate ventilation and avoid installation in panels containing
devices that may cause it to operate outside the specified temperature limits;
Install the product away from sources that may generate electromagnetic disturbances such as:
motors, contactors, relays, solenoid valves, etc;
DUE TO YOUR CONSTANT EVOLUTION, THE FULL GAUGE CONTROLS RESERVES THE RIGHT TO
CHANGE THE INFORMATION CONTAINED IN THIS MANUAL AT ANY TIME WITHOUT NOTICE.
Temperature unit indicator led
MUL
TIFG-01T
-14850