EN
ELECTRICAL CONNECTIONS
The connection of the product to the power sup-
ply must be carried out in compliance with the in-
ternational and local regulations in force.
The interconnection of any separate part of this
appliance must be carried out by a qualified tech-
nician in compliance with the wiring regulations.
The connection to the power supply must be by
means of a plug and it can also be done by the
end user.
Any liability in case of accidents caused by failure
to arrange the earth connection or failure to ar-
range it correctly is hereby declined.
The controls located under the glass of the hob
have a cable, which must be connected to the
corresponding cable coming out of the control
box (Fig. 13 - A).
Connect the cable of the blower assembly to the
terminal located in the grey plastic box, see Fig.
13 - B.
The SEM cable must be located inside the box,
so that it does not touch the power bridge (SELV).
Wires must not be cut. The SEM cable must be
blocked with the cable retainer, as shown in Fig.
18.
SEM16-E
A black colored wire can be found in a plastic
bag, in the terminal area inside the control box.
This wire determines the timer of the 4th speed,
as per EU65 “Energy Label” and EU66 “Ecode-
sign” regulations issued by the European Com-
mission. It must be connected in correspondence
with the yellow and orange wires.
The appliance can be disconnected from power
supply either by disconnecting the accessible
plug or by arranging a switch in the main wiring
harness. This last solution is applicable provided
that there is a separation of the contacts in all
the poles, allowing full disconnection of the ap-
pliance in case of Cathegory III Overvoltage. The
opening gap of the contacts must be 3 mm wide.
29
FCLHD 9041 HID TS BK
Summary of Contents for FCLHD 8041 HID TS BK
Page 2: ......
Page 3: ...3 FCLHD 9041 HID TS BK IMMAGINI PICTURES DESSINS IMÁGENES ABBILDUNGEN ...
Page 5: ...IT SEM16 E 1 MOTORE SEM16 E 2 CONVOGLIATORE ARIA 3 CABLAGGIO ELETTRICO 5 FCLHD 9041 HID TS BK ...
Page 7: ...8 9 12 10 11 7 7 FCLHD 9041 HID TS BK ...
Page 8: ...14 13 16 15 8 FCLHD 9041 HID TS BK ...
Page 9: ...17 19 18 9 FCLHD 9041 HID TS BK ...
Page 10: ...20 10 FCLHD 9041 HID TS BK ...
Page 22: ...EN SEM16 E 1 SEM16 E BLOWER 2 AIR CONVEYOR 3 ELECTRICAL WIRING 22 FCLHD 9041 HID TS BK ...
Page 34: ...FR SEM16 E 1 MOTEUR SEM16 E 2 CONVOYEUR D AIR 3 CÂBLAGE ÉLECTRIQUE 34 FCLHD 9041 HID TS BK ...
Page 58: ...DE SEM16 E 1 SEM16 E MOTOR 2 LUFTFÖRDERER 3 VERDRAHTUNG 58 FCLHD 9041 HID TS BK ...
Page 70: ...70 FCLHD 9041 HID TS BK ...
Page 71: ......
Page 72: ...00000000000 11 19 SINCE 1949 ...