Error code
description
Possible causes
Error recovery
E/3
Unsustable pot, e.g.
lost of the magnetic
characteristics because
of temperature in the
bottom.
Pot creates on the
modul an improper
operating point which
can destroy devices,
e.g. IGBT.
1. the error is
automaticly cancelled
after 8s and the cooking
zone can be used
again. In case of further
upcoming errors the post
have to be changed.
2. the modul has to be
changed if the error
comes without an pot on
the cooking zone.
E/4
Unconfigured induction
modul (all induction
modul answer to UI, but
any element is related
to the effected cooking
zone).
Induction modul is not
configured.
1. Delet the hob
configuration and
activate the manual
configuration.
2. Start the UI service
menue to configure the
imduction modul.
3. If the listed points are
not succesful replace
the modul.
E/5
No communication
between UI and
inducation modul.
No power supply of
induction modul
Mal cabeling or defect
of.
Check power and lin
connections is the
connention ok, replace
the modul.
E/6
Main power disturbace .
1. Failure in main power
frequency detection.
Check main power
voltage and frequency,
if ok.
Summary of Contents for CH 1004 ID TS
Page 1: ...CREATIVE CH 1004 ID TS CHM 904 ID TS CH 904 ID TS CH 804 ID TS CH 604 ID TS ...
Page 2: ......
Page 20: ...20 I Fig 9 ...
Page 21: ...21 I Tenendo conto del fattore di contemporaneità Fig 10 Fig 11 ...
Page 28: ......
Page 45: ...45 GB Fig 9 ...
Page 46: ...46 GB Considering contemporaneity factor Fig 10 Fig 11 ...
Page 70: ...70 FR Fig 9 ...
Page 71: ...71 FR En tenant compte du coefficient de simultanéité Fig 10 Fig 11 ...
Page 78: ......
Page 96: ...96 DE Abb 9 ...
Page 97: ...97 DE Bei Gleichzéitigkeitsfaktor Abb 10 Abb 11 ...
Page 104: ......
Page 122: ...122 ES Fig 9 ...
Page 123: ...123 ES Tomando en cuenta el factor de simultaneidad Fig 10 Fig 11 ...
Page 130: ......
Page 148: ...148 NL Fig 9 ...
Page 149: ...149 NL In aanmerking van de Geleijktijdigheidsfactor Fig 10 Fig 11 ...
Page 156: ......
Page 174: ...174 PT Fig 9 ...
Page 175: ...175 PT Tomando em consideração o fator de simultaneidade Fig 10 Fig 11 ...
Page 182: ...182 PT Cod 1 008 87 0 2ed ...
Page 183: ......