Fujitsu UTB-Series Operating Manual Download Page 4

En-3

PREPARATORY OPERATION

To set the operation mode

OPERATION

 It is possible to make the operation settings for all indoor units or individual units.

To start/stop operation

Hold down the PROGRAM (CLOCK ADJUST) button for 2
seconds or more.

2

Press the DAY button and select the
current day.

 appears around the selected

day.

Press the Set Time buttons to set the current time.
Press repeatedly to adjust the current time in 1-minute increments. Press and
hold to adjust the current time in 10-minute increments.

ex. Monday 10:00 (24-hour display)

Press again the PROGRAM (CLOCK
ADJUST) button to end.

CLOCK ADJUST

1

3

4

Press the ALL ON button or the ALL OFF button to turn on or off all registered indoor units.

Press the Master Control button to set the operation mode.

To set the current day and time

● 

Operation mode setting

AUTO

COOL

DRY

FAN

HEAT

CLOCK ADJUST

DAY

 S          M          T          W         T         F         S

SUN

MON

TUE

WED

THU

FRI

SAT

Reverse Advance

ALL

ON

ALL
OFF

* With cover closed

Press the ON/OFF button for the corresponding indoor unit.

* With cover open

Press the Start/Stop button for selected indoor unit(s).

ON

OFF

Temperature setting range

AUTO ............................................................ 18 to 30 °C
COOL/DRY .................................................... 18 to 30 °C
HEAT ............................................................. 10 to 30 °C

Raise

Press the Set Temperature buttons to set the room temperature.

● 

Room temperature setting

* AUTO and FAN cannot be selected for “HEAT PUMP MODELS.”
* HEAT cannot be selected for “COOLING ONLY MODELS.”

Lower

Press the Fan Control button to set the fan speed.

* According to the initial setting, the heating temperature range from 10 to 15 °C

cannot be set. In addition, the temperature range from 10 to 15 °C is invalid de-
pending on the model even if it can be set.

● 

Fan speed setting

AUTO

HIGH

MED

LOW

* If DRY is selected, the fan speed can be set to AUTO only.

Summary of Contents for UTB-Series

Page 1: ...ONER OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ MANUAL DE INSTRUÇÕES Remote Controller UTB D GROUP REMOTE CONTROLLER WIRED TYPE TM English Deutsch Français Español Italiano EλληvIkά Русский Português ...

Page 2: ...allation of the controller If a problem burning smell etc occurs turn off the electrical breaker immediately to stop operation and then consult authorized service personnel If the wiring cord is damaged contact your service representative for instruction CAUTION This mark indicates procedures which if improperly performed might possibly result in personal harm to the user or damage to property Do ...

Page 3: ...ster Control Button Set Temperature Button Timer and Clock Display and setting Displaying the Status and Controlling indoor units Indoor Unit Operation Indicators This shows the operating status and timer op eration status for each of the indoor units On Off Timer operation Selection Operation Lamp This is on if any of the indoor units is operating This flashes if any of the indoor units has malfu...

Page 4: ...ion mode To set the current day and time Operation mode setting AUTO COOL DRY FAN HEAT CLOCK ADJUST DAY S M T W T F S SUN MON TUE WED THU FRI SAT Reverse Advance ALL ON ALL OFF With cover closed Press the ON OFF button for the corresponding indoor unit With cover open Press the Start Stop button for selected indoor unit s ON OFF Temperature setting range AUTO 18 to 30 C COOL DRY 18 to 30 C HEAT 10...

Page 5: ... or cancel the WEEKLY timers for all indoor units If any of the indoor units are in the timer mode pressing this button cancels the timers for all indoor units If none of the indoor units are in the timer mode pressing this button starts the timers for all indoor units Press the Timer Mode DELETE button to start or cancel the WEEKLY timers for the indoor units se lected by the Select button Press ...

Page 6: ...next timer for the same day TIMER 1 TIMER 2 TIMER 3 TIMER 4 Then press the ENTER button to proceed to the time setting and repeat steps from 4 to 5 Repeat steps 3 to 5 to set the timer for another day of the week To delete the operating time WEEKLY TIMER Timer setting 8 When the operating time is set the mark appears ex TIMER 1 will start operation at 8 00 on COOL with a set ting of 20 C 1 Press t...

Page 7: ...sonnel SPECIFICATIONS GROUP REMOTE CONTROLLER WIRED TYPE MODEL POWER DIMENSIONS WEIGHT HEIGHT mm WIDTH mm DEPTH mm WEIGHT g UTB D DC 12 V 120 120 17 160 MONITOR MODE The operation status of each indoor unit can be checked in the Monitor mode To enter the Monitor mode The display automatically switches to the Monitor mode after 60 seconds if no button is pressed is not shown in the Monitor mode Pre...

Reviews: