Fujitsu UTB-Series Operating Manual Download Page 1

KEEP THIS MANUAL
FOR FUTURE REFERENCE

FUJITSU GENERAL LIMITED

P/N9374708017

O

PERATING 

M

ANUAL

AIR CONDITIONER

OPERATING MANUAL

BEDIENUNGSANLEITUNG

MODE D’EMPLOI

MANUAL DE FUNCIONAMIENTO

MANUALE DI ISTRUZIONI

ΕΓΧΕΙΡΙ∆ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ

РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ

MANUAL DE INSTRUÇÕES

Remote Controller

UTB- D

GROUP REMOTE
CONTROLLER
(WIRED TYPE)

TM

English

Deutsch

Français

Español

Italiano

EλληvIkά

Ру

сс

кий

Por

tuguês

Summary of Contents for UTB-Series

Page 1: ...ONER OPERATING MANUAL BEDIENUNGSANLEITUNG MODE D EMPLOI MANUAL DE FUNCIONAMIENTO MANUALE DI ISTRUZIONI ΕΓΧΕΙΡΙ ΙΟ ΛΕΙΤΟΥΡΓΙΑΣ РУКОВОДСТВО ПО ЭКСПЛУАТАЦИИ MANUAL DE INSTRUÇÕES Remote Controller UTB D GROUP REMOTE CONTROLLER WIRED TYPE TM English Deutsch Français Español Italiano EλληvIkά Русский Português ...

Page 2: ...allation of the controller If a problem burning smell etc occurs turn off the electrical breaker immediately to stop operation and then consult authorized service personnel If the wiring cord is damaged contact your service representative for instruction CAUTION This mark indicates procedures which if improperly performed might possibly result in personal harm to the user or damage to property Do ...

Page 3: ...ster Control Button Set Temperature Button Timer and Clock Display and setting Displaying the Status and Controlling indoor units Indoor Unit Operation Indicators This shows the operating status and timer op eration status for each of the indoor units On Off Timer operation Selection Operation Lamp This is on if any of the indoor units is operating This flashes if any of the indoor units has malfu...

Page 4: ...ion mode To set the current day and time Operation mode setting AUTO COOL DRY FAN HEAT CLOCK ADJUST DAY S M T W T F S SUN MON TUE WED THU FRI SAT Reverse Advance ALL ON ALL OFF With cover closed Press the ON OFF button for the corresponding indoor unit With cover open Press the Start Stop button for selected indoor unit s ON OFF Temperature setting range AUTO 18 to 30 C COOL DRY 18 to 30 C HEAT 10...

Page 5: ... or cancel the WEEKLY timers for all indoor units If any of the indoor units are in the timer mode pressing this button cancels the timers for all indoor units If none of the indoor units are in the timer mode pressing this button starts the timers for all indoor units Press the Timer Mode DELETE button to start or cancel the WEEKLY timers for the indoor units se lected by the Select button Press ...

Page 6: ...next timer for the same day TIMER 1 TIMER 2 TIMER 3 TIMER 4 Then press the ENTER button to proceed to the time setting and repeat steps from 4 to 5 Repeat steps 3 to 5 to set the timer for another day of the week To delete the operating time WEEKLY TIMER Timer setting 8 When the operating time is set the mark appears ex TIMER 1 will start operation at 8 00 on COOL with a set ting of 20 C 1 Press t...

Page 7: ...sonnel SPECIFICATIONS GROUP REMOTE CONTROLLER WIRED TYPE MODEL POWER DIMENSIONS WEIGHT HEIGHT mm WIDTH mm DEPTH mm WEIGHT g UTB D DC 12 V 120 120 17 160 MONITOR MODE The operation status of each indoor unit can be checked in the Monitor mode To enter the Monitor mode The display automatically switches to the Monitor mode after 60 seconds if no button is pressed is not shown in the Monitor mode Pre...