Caution
-
To
completely
shut
down
the
system,
all
the
power
cords
must
be
removed.
If
the
power
cords
are
not
removed,
an
electrical
failure
may
occur.
XSCF>
showlogs
error
■
Before
replacing
the
motherboard
unit,
execute
the
dumpconfig
command
to
save
the
system
setting
information.
When
the
motherboard
unit
is
replaced,
the
CPU
Activation
setting
information
and
CPU
Activation
key
may
be
deleted.
To
restore
the
CPU
Activation
setting
information
and
CPU
Activation
key
that
have
been
saved
with
the
dumpconfig
command,
execute
the
restoreconfig
command.
For
details,
see
"10.10
Saving/Restoring
XSCF
Setting
Information"
in
the
Fujitsu
M10/SPARC
M10
Systems
System
Operation
and
Administration
Guide
.
■
Set
the
system
time.
After
replacement
of
the
motherboard
unit
has
been
completed,
set
the
system
time.
For
details
of
the
setting
method,
see
"3.6.6
Configuring
the
system
time"
in
the
SPARC
M10
Systems
System
Operation
and
Administration
Guide
.
■
Check
the
XCP
version.
If
you
replace
the
motherboard
unit
and
switch
the
microSD
card,
the
CMU
firmware
versions
displayed
for
the
current
and
reserve
XCPs
by
the
version
command
do
not
match
when
you
check
the
XCP
firmware
version
after
executing
the
testsb
command.
This
does
not
affect
system
operation.
If
you
start
the
system
when
the
current
and
reserve
XCPs
have
been
switched,
the
CMU
firmware
stored
on
the
microSD
card
is
automatically
applied.
■
The
type
of
motherboard
unit
varies
depending
on
the
number
of
CPU
clocks.
7.3
Preparing
the
Motherboard
Unit
for
Removal
This
section
explains
the
preparations
that
must
be
completed
prior
to
removing
the
motherboard
unit.
The
preparation
procedure
is
same
regardless
of
whether
the
system
is
configured
with
or
without
a
hardware
RAID.
1.
Open
the
rack
door.
2.
Log
in
to
the
XSCF
shell.
3.
Execute
the
showlogs
command
to
identify
the
motherboard
unit
requiring
maintenance.
For
details,
see
."
4.
Confirm
the
hardware
and
software
configurations.
For
details,
see
5.
Stop
the
system.
Fujitsu
M10-1/SPARC
M10-1
Service
Manual
・
November
2014
62
Summary of Contents for SPARC M10-1
Page 1: ...Fujitsu M10 1 SPARC M10 1 Service Manual Manual Code C120 E681 08EN November 2014 ...
Page 12: ...Fujitsu M10 1 SPARC M10 1 Service Manual November 2014 xii ...
Page 23: ...Figure 1 4 Removing the power cords Chapter 1 Before Starting Maintenance Work 7 ...
Page 24: ...Fujitsu M10 1 SPARC M10 1 Service Manual November 2014 8 ...
Page 74: ...Fujitsu M10 1 SPARC M10 1 Service Manual November 2014 58 ...
Page 122: ...9 Close the rack door Fujitsu M10 1 SPARC M10 1 Service Manual November 2014 106 ...
Page 132: ...Fujitsu M10 1 SPARC M10 1 Service Manual November 2014 116 ...
Page 154: ...Fujitsu M10 1 SPARC M10 1 Service Manual November 2014 138 ...
Page 188: ...Fujitsu M10 1 SPARC M10 1 Service Manual November 2014 172 ...
Page 210: ...Fujitsu M10 1 SPARC M10 1 Service Manual November 2014 194 ...
Page 228: ...Fujitsu M10 1 SPARC M10 1 Service Manual November 2014 212 ...
Page 230: ...Fujitsu M10 1 SPARC M10 1 Service Manual November 2014 214 ...