Servicing Boards and Components
173
Related Information
■
“Install the Power Supply Backplane” on page 173
▼
Install the Power Supply Backplane
1. Mount the power supply backplane to the front of the power supply bay.
Place the backplane over its standoffs. Press down toward the floor of the chassis.
FIGURE:
Installing a Power Supply Backplane (Illustrating an Installation in a SPARC
Enterprise T5240 Server)
2. Secure the power supply backplane with one No. 2 Phillips screw.
3. Install the power distribution board.
See
“Install the Power Distribution Board” on page 167
4. Install the power supplies.
Slide each power supply into its bay until the power supply locks into place.