Chapter 8 Flash Programming of MCU
© Fujitsu Semiconductor Europe GmbH
- 31 -
UG-910097-11
Figure 11: FR Flash programmer
6. The next step is to switch into Program mode. Refer to section 4.2 for a detailed
description. Switch ON the switches SW1-1 and SW1-2 to enter Serial Programming
mode as shown below.
7.
Press the “Full Operation” button to start programming, press the RESET button
(SW3
) and click on ‘OK’.
8. When the download was not successful (message on PC), check the jumper settings
of UART as in step 1 above and the cable connections.
If using UART ‘A’, then check
JP18, JP19, JP20, JP21 and JP22 as well for default settings.
9. After a successful download of the program, set SW1-1 and SW1-2 to OFF in order
to get back to the Run mode and push the RESET button (SW3).
10. The application is flashed in the MCU and starts after the reset.
Figure 12: Switch SW1 on PROG-mode
Figure 13: Switch SW1 on Run-mode (default)