
38
A26361-K881-Z102-4-7619
Installing/Removing the Rack Model into the Rack
Hardware Installation
I
The telescopic rail with assembly bracket (HL) will be secured laterally on
the front left support upright and frontally on the support bracket. The
second telescopic rail will be secured directly laterally on the right
support upright (figure 8).
To fasten the left telescopic rail to the support bracket, no spring nuts are
necessary since the assembly bracket (HL) is equipped with threaded holes.
For adjustment two mounting springs or plugwashers must be pre-installed
in the support bracket (see figure 5 on page 34).
Figure 8: Mounting the telescopic rail in the DataCenter Rack
Ê
Secure the end of the telescopic rail without assembly bracket with two
screws M5 (1) in the rack at the front left support upright.
Please note that the guide nubs of the telescopic rail next to the spring nuts
must fit into the holes in the support upright.