Hardware Installation
Installing/Removing the Rack Model into the Rack
Figure 7: Prepare the left telescopic rail
Ê
Fasten the delivered assembly bracket HL on the rear end of the left
telescopic rail (1) with two screws M5x8 (2) and two hexagonal flange nuts
M5 (3) as shown in figure 4.
When mounting the left telescopic rail in the DataCenter Rack, the supplied
support bracket must first be mounted level with the device on the rear left
support upright.
Ê
Mark the position of the attachment points for the telescopic rails and for the
server (front panel) on the support uprights (four height units).
Ê
Mount the support bracket at the appropriate height on the left rear support
upright as described in the Technical Manual of the DataCenter Rack.
Ê
Place the spring nuts to fasten the telescopic rails in the groove of the
support uprights at the marked attachment points.
Ê
Adjust the position of the nuts in the groove until they lock into the correct
position.