A26361-K881-Z102-4-7619
33
Hardware Installation
Installing/Removing the Rack Model into the Rack
Figure 4: Prepare the telescopic rails with the assembly brackets
Ê
Fasten the delivered assembly bracket VL on the front end of the left
telescopic rail (1) with two screws M5x8 (2) as shown in figure 4.
Ê
Fasten the delivered assembly bracket HL on the rear end of the left
telescopic rail (3) with two screws M5x8 (4) and two hexagonal flange nuts
M5 as shown in figure 4.
Ê
Repeat the procedure also for the right telescopic rail and the corresponding
assembly brackets VR and HR.
For mounting the left telescopic rail in the PRIMECENTER Rack, the delivered
support bracket must first be mounted on the rear left support upright. The
bracket must be mounted level with the lower edge of the device.
Ê
Mount the support bracket at the appropriate height on the left rear support
upright as described in the Technical Manual of the PRIMECENTER Rack.