TX300 S5
Options Guide
103
Conversion from a floorstand model to a rack model
12.3
Removing the foot mounting rail
Figure 72: Removing the foot mounting rail
Ê
Loosen the three screws (1) of the foot mounting rail.
Ê
Slide the foot mounting rail backward (2) until the hooks (a) unlock.
Ê
Remove the foot mounting rail (3).
I
The foot mounting rail is no longer required.
12.4
Accessible drives and operating panel
module
The drive cage for the accessible drives is constructed in such a way that the
accessible drives and the operating panel module can be taken out simply,
turned through 90° to the left, and then be reinstalled.
Ê
Remove the dummy covers from the drive cage (
Ê
Unplug the cables from the system board or the accessible drives and
remove the drives from the drive cage.
Ê
Pull the operating panel module forward out if its mounting location until you
can pull the I²C cable, the ribbon cable, and the USB cable out of the
operating panel module. Remove the three cables.
Ê
Remove the operating panel module.
a
1
1
1
3
2