88
Operating manual
TX300
S5
Incorrect date and time
Troubleshooting and tips
7.6
Incorrect date and time
Ê
Set the date and time in the operating system or in the BIOS Setup under
the
Main
menu, using
System Date
and
System Time
respectively.
I
Note that the operating system may affect the system time. For example,
the operating system time may deviate from the system time under Linux,
and would overwrite the system time in the default setting on shutdown.
If the date and time are still wrong after the server has been switched off and
back on again, replace the lithium battery (for a description refer to the Technical
Manual for the D2619 system board) or contact our customer service team.
7.7
Hard disk drive error messages at system
boot
Various hard disk drive error messages may occur when the system is rebooted.
These error messages are caused by modifications in the selected RAID config-
uration.
RAID controller configuration incorrect
Ê
Check and correct the settings for the drives using the RAID controller
configuration program.
I
Further information is provided in the "Integrated RAID for SAS User’s
Guide" (on the PRIMERGY ServerView Suite DVD 2 under
Industry
Standard Servers
-
Expansion Cards
-
Storage Adapters
-
LSI RAID / SCSI
Controllers
) or in the "Modular RAID Controller Installation Guide" (on the
PRIMERGY ServerView Suite DVD 2 under
Industry Standard Servers
-
Expansion Cards
-
Storage Adapters
-
LSI RAID / SCSI Controllers
).
For more information on configuring the controller, see section
"Config-
uring the server" on page 79
.