TX2550 M4
Upgrade and Maintenance Manual
247
Hard disk drive (HDD) / solid state drive (SSD)
Ê
"Removing the system air duct" on page 67
Ê
Remove the fan bridge, see section
"Handling fan bridges" on page 90
.
7.5.3.2
Removing the 8x 2.5-inch HDD/SSD extension box
Ê
Remove all cables from the 8x 2.5-inch HDD/SSD extension box backplane.
Ê
Disengage the accessible drive locking bar, see section
accessible drive locking bar" on page 94
Figure 160: Removing the 8x 2.5-inch HDD/SSD extension box
Ê
Carefully pull the 8x 2.5-inch HDD/SSD extension box out of its installation
bays.
Ê
Engage the locking bar, see section
"Closing the accessible drive locking
.