72
Operating Manual
TX140
S2
Starting up and operation
Ê
Follow the on-screen instructions (see also section
"Configuring the
server and installing the operating system with the ServerView
Installation Manager" on page 75
or section
"Configuring the server and
installing the operating system without the ServerView Installation
Manager" on page 76
).
–
System already installed
:
Ê
Press the On/Off button (see item 12 in figure
8 on page 62
).
The server is switched on, performs a system test and boots the
operating system.
Switching the server off
The power-on indicator lights up green (see item 11 in figure
8 on page 62
).
Ê
Shut down the operating system properly.
The server is switched off automatically and goes into standby mode. The
power-on indicator lights up orange.
I
If the operating system does not switch the server off automatically, press
the On/Off button for at least four seconds and/or send a corresponding
control signal.
Other On/Off options
Besides the On/Off button, the server can be switched ON and OFF in the
following ways:
–
Timer-controlled switch-on/off
Using the ServerView Operations Manager or iRMC S4, you can configure
that the server is switched on/off controlled by timer.
–
Ring indicator
The server is switched on by an internal or external modem.
–
Wake up On LAN (WOL)
The server is switched on by a command via the LAN (Magic Packet
TM
).
–
After power failure
The server automatically reboots following a power failure (depending on the
settings in the BIOS or in iRMC S4).
Summary of Contents for PRIMERGY TX140 S2
Page 1: ...Operating Manual English PRIMERGY TX140 S2 Server Operating Manual July 2013 ...
Page 6: ...Operating Manual TX140 S2 ...
Page 10: ...Operating Manual TX140 S2 Contents ...
Page 14: ...14 Operating Manual TX140 S2 Introduction ...
Page 58: ...58 Operating Manual TX140 S2 Hardware installation ...
Page 78: ...78 Operating Manual TX140 S2 Starting up and operation ...
Page 80: ...80 Operating Manual TX140 S2 Property and data protection ...