Ensure that the two noses of the HDD fan module (see close-up) fit with the
recesses of the HDD cage (see circle).
▶
Ensure that the fans freely rotate.
▶
Connect the fan cable of HDD fan module 1 to the system board connector
"FAN4 SYS".
▶
Connect the fan cable of HDD fan module 2 to the system board connector
"FAN2 SYS".
4.12.3 Removing the HDD fan module (2.5-inch HDD
variant)
▶
Disconnect the corresponding fan cable from the system board.
Figure 24: Removing the HDD fan module
▶
Press on the green tab (see circle) and remove the HDD fan module from
the HDD cage.
Basic hardware procedures
TX1320 M5
Upgrade and Maintenance Manual
67