Tools:
– Phillips PH2 / (+) No. 2 screw driver (only for replacing the slot
bracket)
Note on network settings recovery
When replacing network controllers or the system board, network
configuration settings in the OS will be lost and replaced by default
values. This applies to all static IP address and LAN teaming
configurations.
Ensure to note down your current network settings before replacing a
network controller or the system board.
Preliminary steps
▶
"Locating the defective server" on page 43
.
▶
"Suspending BitLocker functionality" on page 71
.
▶
If applicable, ensure to note down your current network settings.
▶
"Shutting down the server" on page 45
▶
"Disconnecting the power cord" on page 46
▶
If applicable, disconnect external cables from the expansion card.
▶
"Getting access to the component" on page 48
▶
"Locating the defective component" on page 44
.
Removing an expansion card
▶
Remove the expansion card, see
"Removing expansion cards" on page 203
.
▶
If the slot bracket on the defective expansion card is to be reused, remove it
from the expansion card, see
"Removing a slot bracket" on page 186
Installing an expansion card
▶
If applicable, install the slot bracket, see
"Installing the slot cover" on
.
▶
Install the expansion card, see
"Installing expansion cards" on page 195
Expansion cards and backup units
206
Upgrade and Maintenance Manual
TX1320 M5
Summary of Contents for PRIMERGY TX1320 M5
Page 70: ...Basic hardware procedures 70 Upgrade and Maintenance Manual TX1320 M5 ...
Page 132: ...Power supply unit PSU 132 Upgrade and Maintenance Manual TX1320 M5 ...
Page 180: ...Fans 180 Upgrade and Maintenance Manual TX1320 M5 ...
Page 266: ...Accessible drives 266 Upgrade and Maintenance Manual TX1320 M5 ...
Page 272: ...Front panel 272 Upgrade and Maintenance Manual TX1320 M5 ...
Page 280: ...Front USB connector 280 Upgrade and Maintenance Manual TX1320 M5 ...
Page 298: ...Dust cover 298 Upgrade and Maintenance Manual TX1320 M5 ...
Page 346: ...System board and components 346 Upgrade and Maintenance Manual TX1320 M5 ...
Page 402: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...