Starting up and operation
3
Global Error
indicator,
see also
"iRMC-
related
status
signals" on
page 67
off
No critical event detected (non CSS
component).
orange on
Prefailure event detected (non CSS
component).
orange
flashing
Non CSS component failure
detected.
Possible causes:
– System is out of the temperature
specified range
– Defective sensor
– CPU error
– Error detected by server
management software
4
HDD/SSD
activity
indicator
green
flashing
Data access in progress.
5
Power-on
indicator
off
The server is switched off.
green on
– The server has been switched on
but Power Cycle Delay settings
delay it from turning on for a
specified time.
– The server is switched on and
operating normally.
green
flashing
slowly
The BMC firmware is starting up
after the server has been connected
to the mains.
Pos.
Label
Indicator
Status
Description
!