background image

12

Service Supplement

 

SX980 S1 / SX980 S2

Introduction

Summary of Contents for PRIMERGY SX980 S1

Page 1: ...Service Supplement English PRIMERGY SX980 S1 SX980 S2 Storage Blade Service Supplement Edition October 2012 ...

Page 2: ...on mbH www cognitas de Copyright 2012 Fujitsu Technology Solutions GmbH All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers The contents of this manual may be revised without prior notice Fujitsu assumes no liability for damages to third party copyrights or other rights ...

Page 3: ... these components beyond their operating life may result in electrolyte leakage or depletion potentially causing emission of foul odor or smoke As a guideline in a normal office environment 25 C operating life is not expected to be reached within the maintenance support period 5 years However operating life may be reached more quickly if for example the product is used in a hot environment The cus...

Page 4: ...nal Computer issued by JEITA the Japan Electronics and Information Technology Industries Association Technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents produced by Fujitsu may contain technology controlled by the Foreign Exchange and Foreign Trade Control Law of Japan Documents which contain such technology should not be exported from Japan or transferre...

Page 5: ... S1 SX980 S2 Service Supplement Only for the Japanese market I Although described in this manual some sections do not apply to the Japanese market These options and routines include CSS Customer Self Service ...

Page 6: ...Service Supplement SX980 S1 SX980 S2 ...

Page 7: ...outines 17 4 1 Preparation 17 4 1 1 Removing the storage blade from the system unit 17 4 2 Replacing the complete storage blade 18 5 Appendix 19 5 1 PRIMERGY SX980 S1 19 5 1 1 SX980 S1 storage blade as spare part 19 5 1 2 SX980 S1 storage blade cable plan 20 5 2 PRIMERGY SX980 S2 21 5 2 1 SX980 S2 storage blade as spare part 21 5 2 2 SX980 S2 storage blade cable plan 22 5 3 Installing drive module...

Page 8: ...Service Supplement SX980 S1 SX980 S2 Contents ...

Page 9: ...980 S2 storage blades can be installed per BX900 S1 BX900 S2 system unit 1 1 Concept and target groups This Service Supplement completes the information given in the Operating Manual The activities described in this manual may only be performed by service personnel 1 2 Documentation overview Service DVD PRIMERGY Service partners of Fujitsu Technology Solutions can order a PRIMERGY Service DVD On t...

Page 10: ...anual Installation and operation among other things Installation in the system units Starting up Operation Installation removal of components Hot plug hard disk drives and solid state drives Replacement routines SX980 S1 SX980 S2 storage blade complete with cables Service Supplement Board layouts and cable plan Table 1 Overview of the documentation for PRIMERGY SX980 S1 SX980 S2 storage blade ...

Page 11: ...or menu items Quotation marks indicate names of chapters and terms that are being emphasized Ê describes activities that must be performed in the order shown V CAUTION pay particular attention to texts marked with this symbol Failure to observe this warning may endanger your life destroy the system or lead to the loss of data I indicates additional information notes and tips ...

Page 12: ...12 Service Supplement SX980 S1 SX980 S2 Introduction ...

Page 13: ... Service DVD are available print out the PDF files if necessary You will definitely need the Operating Manual for the system unit and the server blades Ê Switch off the related server blade s and pull the storage blade out of the slot as described in section Removing the storage blade from the system unit on page 17 Ê Push the storage blade in the slot These procedures are described in the Operati...

Page 14: ...14 Service Supplement SX980 S1 SX980 S2 Procedure ...

Page 15: ...ine Wait until the device has acclimatized to room temperature and is absolutely dry before starting it up Material damage may be caused to the device if this requirement is not observed Transport the device only in the original packaging or in packaging that protects it from knocks and jolts Installation and operation V CAUTION Never connect or disconnect data transmission lines during a storm li...

Page 16: ...containing ESDs You must always discharge yourself of static charges e g by touching a grounded object before working The equipment and tools you use must be free of static charges Only touch the components at the positions highlighted in green Touchpoints Do not touch any exposed pins or conductors on a component Use a grounding cable designed for this purpose to connect yourself to the system un...

Page 17: ...ch off the related server blade s 4 1 1 Removing the storage blade from the system unit I You will find a detailed description of removing installing the storage blade out of into the system unit in the SX980 S1 SX980 S2 storage blade Operating Manual Ê Switch off the related server blade s either using the On Off button on the server blade or using the Web interface of the management blade see th...

Page 18: ... the individual HDD SSDs in the storage blade for reinstallation Ê Only for the japanese market Remove the storage blade as described in section Removing the storage blade from the system unit on page 17 Use the cover from the defective storage blade I It is necessary to copy the model name and the serial number described in the label that exists in the ID card Please use a new label Ê Insert the ...

Page 19: ...1 storage blade as spare part Part number S26361 K1383 V901 The spare part contains all the components shown below Figure 2 SX980 S1 storage blade as spare part with cables Pos Description 1 Control Panel 2 Drive Backplane 3 Expander Board 4 Interposer Board 5 SAS Connection Board 0 1 2 ...

Page 20: ...storage blade cable plan Figure 3 Cable plan for SX980 S1 storage blade X103 X102 SAS Connection Board 1 X1 X2 Expander Board 1 Drive Backplane X13 X11 X12 Interposer Board X104 X103 X102 X105 Control Panel X103 X102 SAS Connection Board 2 Key Signal Power SAS P1 P2 ...

Page 21: ... storage blade as spare part Part number S26361 K1383 V902 The spare part contains all the components shown below Figure 4 SX980 S2 storage blade as spare part with cables Pos Description 1 Control Panel 2 Drive Backplane 3 Expander Board 4 Interposer Board 5 SAS Connection Board 2 1 0 ...

Page 22: ...able plan Figure 5 Cable plan for SX980 S2 storage blade X103 X102 SAS Connection Board 1 X1 X2 Expander Board 1 Expander Board 2 X1 X2 Drive Backplane X13 X11 X12 Interposer Board X104 X103 X102 X105 Control Panel X103 X102 SAS Connection Board 2 Key Signal Power SAS P2 P2 P1 P1 ...

Page 23: ...SX980 S1 SX980 S2 Service Supplement 23 Appendix 5 3 Installing drive modules The SX980 S1 SX980 S2 storage blade has 10 slots for 2 5 SAS HDD SSD drive modules Figure 6 Installing drive modules ...

Page 24: ...24 Service Supplement SX980 S1 SX980 S2 Appendix ...

Reviews: