140
Chapter 6 Installing Internal Options
6.3.2 Installable CPUs and Notes
Installable CPUs
The following types of CPUs can be installed on this server. When installing an optional CPU, the two
CPUs must have the same product name (same frequency/cache size).
Before installing an optional CPU, see "Appendix B.1 CPU" (
p.246) to check the packaged product.
6.3.3 How to Install a CPU
1
Turn off the power and all peripheral devices, and pull the server out from the
rack to remove the top cover.
"6.2.1 How to Remove the Top Cover" (p.136)
2
Touch a metal part of the server to discharge static electricity.
3
Remove the fan duct.
"6.2.2 How to Remove the Fan Duct" (p.138)
4
Remove the socket protection cover by pulling the tab up.
table: List of Installable CPUs
Product name
Product ID
Processor Xeon E5205 (1.86GHz)
PG-FG42G
Processor Xeon X5260 (3.33GHz)
PG-FG42H
Processor Xeon X5270 (3.50GHz)
PG-FG42N
Processor Xeon E5405 (2GHz)
PG-FG42J
Processor Xeon E5420 (2.50GHz)
PG-FG42K
Processor Xeon X5460 (3.16GHz)
PG-FG42L
Processor Xeon X5470 (3.33GHz)
PG-FG42M
Socket
protection cover
Tab