16.6.2 Installing an M.2 SSD
Upgrade and Repair Unit
(URU)
Hardware: 5 minutes
Software: 15 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver (for cover 2)
Preliminary steps
▶
If applicable,
"Removing the front cover with lock" on page 52
▶
"Shutting down the server" on page 52
▶
"Disconnecting the power cord" on page 53
▶
"Getting access to the component" on page 56
Installing the M.2 SSD
CAUTION
An M.2 SSD in M.2 SSD1 is not recognized, if M.2 SSD2 is free.
▶
Install the M.2 SSD2 first.
To support different length of M.2 SSD, the M.2 SSD latch can be
moved to another position.
System board and components
498
Upgrade and Maintenance Manual
RX2540 M6