8.11
Ambient conditions
All temperature ratings shown are valid for sea level. An altitude derating of
1 °C per 300 m to 3048 m is applicable.
Environment class 3K2
Environment class 2K2
EN 60721 / IEC 721 Part 3-3
EN 60721 / IEC 721 Part 3-2
Temperature
● Operation (3K2)
10 °C ... 35 °C
5 °C ... 40 °C (with ATD 40 °C)
5 °C ... 45 °C (with ATD 45 °C)
● Transport (2K2)
-25 °C ... 60 °C
Humidity
10% ... 85% (non condensing)
Condensation during operation must be avoided!
PRIMERGY servers are designed for the usage with operating
temperatures of up to 35 °C. There could be configurations that are not
able to work within this normal operation class. Please refer to
Datasheet and Fujitsu WebArchitect (
) to obtain detailed information on the corresponding
configurations.
8.12
Noise level
The acoustic noise values are depending on the system configuration.
typical configuration
2x PSU / 2x CPU
max. configuration
2x PSU / 2x CPU
Sound power level L
WAd
(ISO 9296)
< 5.3 B (standby)
< 6.1 B (operation)
< 7.3 B (standby)
< 7.5 B (operation)
Sound pressure level at
adjacent workstation
L
pAm
(ISO 9296)
< 34.4 dB(A) (standby)
< 43.4 dB(A) (operation)
< 55.2 dB(A) (standby)
< 55.6 dB(A) (operation)
Technical data
RX2540 M6
Operating Manual
111
Summary of Contents for PRIMERGY RX2540 M6
Page 1: ...FUJITSU Server PRIMERGY RX2540 M6 Operating Manual Operating Manual English 08 2021 ...
Page 12: ...9 Warranty and service 121 Content Operating Manual RX2540 M6 ...
Page 14: ...Introduction 14 Operating Manual RX2540 M6 ...
Page 104: ...Troubleshooting and tips 104 Operating Manual RX2540 M6 ...