300
Upgrade and Maintenance Manual
RX2540 M2
Expansion cards and backup units
8.6.3.4
Installing a GPGPU card in a riser module
Ê
Install the GPGPU card in the riser module as described in section
a GPGPU card in a riser module" on page 286
.
8.6.3.5
Installing the air grid extension to riser module 2
Figure 195: Installing the air grid extension to riser module 2
Ê
Insert the air grid extension.
I
Make sure that the bracket of the riser card holder is positioned
outside the air grid extension (see close-up).
Ê
Fasten the air grid extension with two screws (see circles).
8.6.3.6
Replacing the heat sink (FL)
Ê
Replace the standard CPU heat sink with the CPU heat sink for GPGPU
card as described in section
"Replacing CPU heat sinks" on page 388
8.6.3.7
Removing the rear air grid riser module 2
Ê
Remove the rear air grid as described in section
.