When the system board is replaced, the settings in the
Security
tab on
the BIOS setup menu are not automatically transferred, so you must
manually restore the BIOS settings.
The settings related to
Security
block all data writing in order to prevent
data tampering from external sources such as applications. Restoring
BIOS settings is also blocked according to this specification.
Ensure to note down your current BIOS settings before replacing the
system board.
Note on network settings recovery
When replacing network controllers or the system board, network
configuration settings in the operating system will be lost and replaced
by default values. This applies to all static IP address and LAN teaming
configurations.
Ensure to note down your current network settings before replacing the
system board.
Preliminary steps
▶
"Locating the defective server" on page 43
▶
"Note on network settings recovery" on page 327
▶
"Suspending BitLocker functionality" on page 65
.
▶
"Shutting down the server" on page 45
.
▶
"Disconnecting the power cord" on page 46
.
▶
Disconnect all external cables.
▶
"Getting access to the component" on page 48
▶
"Removing the air duct" on page 63
.
▶
"Removing the defective fan module" on page 180
System board and components
RX1330 M4
Upgrade and Maintenance Manual
327
Summary of Contents for PRIMERGY RX1330 M4
Page 98: ...Basic software procedures 98 Upgrade and Maintenance Manual RX1330 M4 ...
Page 176: ...Hard disk drive HDD solid state drive SSD 176 Upgrade and Maintenance Manual RX1330 M4 ...
Page 290: ...Serial interface 290 Upgrade and Maintenance Manual RX1330 M4 ...
Page 364: ...Appendix A 364 Upgrade and Maintenance Manual RX1330 M4 ...
Page 398: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...