2-30
C122-B001-02EN
CHAPTER 2 General Hardware Configuration
2.10
AC Section (ACS)
This section explains the AC section (ACS).
The ACS has a redundant configuration only for the PRIMEQUEST 440 using dual
power feed.
z
Two power distribution board (PDB) units can be connected to an ACS unit. Three
power supply units (PSUs) can be connected to a PDB.
z
Two PSUs can be used with one AC cable.
z
The primary power feed option consists of six PSUs. Up to 12 PSUs can be
connected to the option.
z
The AC section supports dual power feed as an option.
lists ACS specifications.
Table 2.18
ACS specifications
Item
Specifications
Input
Voltage
Rated voltage
200 to 240 VAC
Number of phases
Single phase
Fluctuation range
+10% to -10%
Frequency
Rated frequency
50/60 Hz
Fluctuation range
2%, -4%