B.3
Manually Installing PSA (Windows Server 2008)
This section describes how to install PSA in Windows Server 2008. You need to log in with Administrator privileges
for installation. To install the PSA as a non-Administrator user with Administrator privileges, right-click the file,
and select [Execute as Administrator] from the menu that appears. Then, install PSA.
Remarks
To operate the PRIMEQUEST 1800E, you need to first install PSA. Otherwise, the following restrictions apply.
- I/O (e.g., PCI Express card, hard disk) failure notification and trap notification to the administrator are
disabled.
- Failure notification using symptom detection and trap notification to the administrator are disabled.
- Threshold exceeded in S.M.A.R.T. monitoring of HDDs
- Operations management software cannot collect information on the partition side.
- Even under an REMCS agreement, no software errors are reported.
B.3.1
Installation flow
For the PSA installation flow, see
CHAPTER 4 Installing the Operating System and Bundled Software
. For details
CHAPTER 6 Work after Operating System Installation (PRIMEQUEST 1800E)
Remarks
- If you use SVIM to install the operating system, you need not install PSA. However, after installation with
SVIM, you need to check and make settings according to
B.3.2 Checks before PSA installation
Settings after PSA installation
.
- After installing PSA, execute the SNMP security setting command (setsnmpsec) before you perform the
operation in the following situations. For details on the command, see 4.8 SNMP Security Setting Command
(setsnmpsec) in the
PRIMEQUEST 1000 Series Tool Reference
(C122-E110EN).
- You will be changing the SNMP Service security setting from [Accept SNMP packets from any host]
to [Accept SNMP packets from these hosts].
- You will be changing the MMB IP address.
- In the initial startup of PSA after installation, the Web-UI may display the error message "E_33077 PSA is
Not Active. (01:0000)" in the [PSA] window. This happens because PSA requires extra time to acquire system
sensor data only during the initial startup. Wait a few minutes. Then, refresh the display.
- If you change the MMB IP address or the management LAN IP address on the partition, be sure to then restart
PSA. Otherwise, a display error may occur in the [PSA] window of the Web-UI. Moreover, PSA would not
be able to post any detected errors.
Notes on configuring Windows Server 2008
- Do not stop the Windows Print Spooler service. The information collection function of the operating system
uses WMI (Windows Management Instrumentation). If the Print Spooler service is stopped, the function
cannot collect the correct configuration information because WMI reports an error.
- If the set value of the following registry key is less than 20000 (20 seconds), the system may hang during
operating system shutdown. Be sure to set a value equal to or greater than 20000 (20 seconds).
HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control
" WaitToKillServiceTimeout" (Type: REG_DWORD / default; 20000)
PRIMEQUEST 1000 Series Installation Manual
APPENDIX B Manual PSA Installation and Uninstallation
249