Note
-
For more information about the dladm(1M) command, please refer to the "System Administration Guide: IP Services" and the "man
pages section 1M: System Administration Commands" of Oracle Documentation.
4.2.1.1 Create a LinkAggregation (dladm create-aggr)
This section explains the dladm create-aggr command for activating LinkAggregation.
- Synopsis
-
Solaris 10 8/07 or later
/usr/sbin/dladm create-aggr -d dev [-d dev] ... key
-d dev: Specify the name of the physical interface (including instance number) belonging to
a LinkAggregation Group (*1)
You can specify one to 255 devices.
key: Specify the key number to identify the LinkAggregation
Specify a number ranging from 1 to 999.
*1: The group means an aggregate unit of the interfaces to distribute, to collect and to make mutually redundant.
-
Solaris 11
/usr/sbin/dladm create-aggr -l ether-link [-l ether-link...] aggr-link
-l ether-link: Specify the name of the physical interface (including instance number)
belonging to a LinkAggregation Group (*2)
You can specify one to 255 devices.
aggr-link: The name of the representative interface.The name of the representative interface.
*2: The group means an aggregate unit of the interfaces to distribute, to collect and to make mutually redundant.
- Description
Creates a LinkAggregation Group.
- Exit Code
0: normal end.
>0: abnormal end.
- Example
Processes to create and activate a LinkAggregation Group are shown below.
- 43 -
Summary of Contents for PCI Gigabit Ethernet
Page 10: ...Figure 1 1 1000Base SX 2ports SE0X7GD2X Figure 1 2 10 100 1000Base T 2ports SE0X7GD1X 4 ...
Page 11: ...Figure 1 3 10 100 1000Base T 4ports SE0X7GQ1X Figure 1 4 10 100 1000Base T 4ports SE0X7GQ2X 5 ...
Page 13: ...Figure 2 1 SE0X7GD2X with Multimode Optical Fiber Cable 7 ...
Page 14: ...Figure 2 2 SE0X7GD1X with Twisted Pair CAT5e Cable 8 ...
Page 15: ...Figure 2 3 SE0X7GQ1X with Twisted Pair CAT5e Cable 9 ...
Page 16: ...Figure 2 4 SE0X7GQ2X with Twisted Pair CAT5e Cable 10 ...