3.3 Defect Management
(3)
Automatic alternate block allocation
•
Automatic alternate block allocation at read operation
If the ARRE flag in the MODE SELECT parameter permits the automatic alternate block allocation,
the HDDs automatically execute the alternate block allocation and data duplication on the defective
data block detected during the READ or READ EXTENDED command. This allocation method is
the same as with the REASSIGN BLOCKS command (alternate sector treatment).
•
Automatic alternate block allocation at write operation
If AWRE flag in the MODE SELECT parameter permits the automatic alternate block allocation, the
HDDs execute two kinds of automatic alternate processing during WRITE command processing as
described below:
Type 1 (Reassignment of Uncorrectable Read Error sector)
1) Commands to be applied
- WRITE
- WRITE
EXTEND
-
WRITE at executing WRITE AND VERIFY
2)
Application
requirements
When any of the above commands is issued to LBA registered in the uncorrectable error log of
the READ command (LBA log of uncorrectable error while the READ command is executed),
the AWRE processing is applied.
3)
AWRE
processing
The following processings are performed when the LBA matches the one in the uncorrectable
error log:
a) Primary media check
- Creates an uncorrectable error pattern (invalid LBA pattern) in the position of the error
LBA, repeats the primary media check up to three times. If the error still occurs after
the check repeated three times, it is judged to be defective. Then, it performs the
alternate processing.
b) Alternate
processing
- Alternate media check
Writes the data that causes an unrecoverable error into the alternate block, and performs
the media check.
(If the alternate block is a defective sector, the block is registered to the G list, another
alternate block is allocated.)
c) SA and defect map update processing (on alternate side)
When an error occurs in the alternate processing, this WRITE command terminates with error.
When the alternate processing normally terminates, the WRITE command is executed.
C141-E266
39
Summary of Contents for MBC2036RC SERIES
Page 1: ...C141 E266 01EN MBC2073RC MBC2036RC HARD DISK DRIVES PRODUCT MANUAL ...
Page 10: ...This page is intentionally left blank ...
Page 16: ...This page is intentionally left blank ...
Page 24: ...This page is intentionally left blank ...
Page 56: ...This page is intentionally left blank ...
Page 82: ...Diagnostics and Maintenance 78 C141 E266 Figure 6 4 Fraction packaging ...
Page 88: ...This page is intentionally left blank ...
Page 94: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 97: ......
Page 98: ......