2. Set the adapter power from OFF to ON (by unplugging and plugging the USB
cable). The reset remains in effect for about 32 to 140 ms after the adapter
power is supplied again.
If the user system and adapter cause an uncontrollable error and the system cannot
be recovered by tool reset generation method 1.), execute tool reset generation
method 2.).
3.3 MCU
Board
For details, refer the following manuals:
•
MB2146-301 Operation Manual
•
MB2146-303 Operation Manual
3.3.1 Connecting the MCU board to the Evaluation board
Align the MCU board and evaluation board facing each other, then plug their mating
connectors together. The connectors are provided with incorrect insertion prevention
keys located diagonally. Position the boards correctly without letting the incorrect
insertion prevention keys interfere with each other and plug connectors together
completely.