C141-E226
6-11
6.3 Operation
Check
6.3.1
Initial seek operation check
If an error is detected during initialization by the initial seek operation check routine at power-on,
the spindle motor of the disk drive stops, and then the disk drive becomes unusable.
For an explanation of the operation check before the initial seek, refer to the Section 5.6.
6.3.2 Operation
test
While the host computer is processing data, the HDD monitors disk drive operation including data
processing, command processing, and seek operations. If the HDD detects an error, the HDD
posts the error to the initiator. The initiator then posts the error to the user.
The user may detect an intermittent or nonfatal error such as abnormal noise, abnormal odor, or
very slow operation.
An error posted in an operation test must be investigated. Replace the disk drive to see whether
the error was caused by the disk drive.
Often, errors posted in an operation test may be caused by the host system. Possible causes include
insufficient power capacity, loose cable connection, insufficient timing or insufficient mechanical
play, and problems related to other systems.
If an operation error is detected by the error detection circuit of the disk drive, an interrupt occurs.
The interrupt is posted to the MCU on the PCA. The MCU stops the currently processed
command, and causes the CHECK CONDITION status to post the error to the initiator.
When receiving the CHECK CONDITION status, the initiator issues a REQUEST SENSE
command to collect detailed information about the error. The initiator then issues a REZERO
UNIT command to return the read/write head to track 00. In normal processing, the HDD itself or
initiator determines how to handle the error (processing retry or stop).
To analyze the error posted in the operation test, reconstruct the conditions in which the error
occurred. Then, start troubleshooting the whole host system by replacing the disk drive.
6.3.3 Diagnostic
test
The diagnostic test is executed to find a faulty subassembly in a faulty disk drive, or to check disk
drive performance. This test is usually a combination of specific disk drive functions or group of
functions. This test may be executed using a different host computers or test equipment and away
from the environment where the error first occurred.
To analyze the error posted in the diagnostic test, reconstruct the conditions in which the error
occurred. Then, look for a possibly faulty subassembly or part of the disk drive.
The procedures to be used in this test depend largely on the type of test equipment used, and are
not covered by this manual.
Summary of Contents for MAW3073NC
Page 10: ...This page is intentionally left blank ...
Page 26: ...This page is intentionally left blank ...
Page 34: ...This page is intentionally left blank ...
Page 50: ...This page is intentionally left blank ...
Page 96: ...This page is intentionally left blank ...
Page 112: ...This page is intentionally left blank ...
Page 122: ...This page is intentionally left blank ...
Page 126: ...This page is intentionally left blank ...
Page 128: ...This page is intentionally left blankw ...
Page 129: ......
Page 130: ......