En-6

To Stop Operation

Press the START/STOP button  (Fig. 6 

R

).

The OPERATION Indicator Lamp (red) (Fig. 3 

5

) will go out.

About AUTO CHANGEOVER Operation

AUTO:

When AUTO CHANGEOVER operation first selected, the fan will oper-
ate at very low speed for about one minute, during which time the unit
detects the room conditions and selects the proper operating mode.

If the differance between thermostat setting and actual room tempera-
ture is more than +4 °F 

 Cooling or dry operation

If the difference between thermostat setting and actual room tempera-
ture is within ±4 °F 

 Monitor operation

If the difference between thermostat setting and actual room tempera-
ture is more than –4 °F 

 Heating operation

When the air conditioner has adjusted your room’s temperature to near
the thermostat setting, it will begin monitor operation. In the monitor
operation mode, the fan will operate at low speed. If the room tem-
perature subsequently changes, the air conditioner will once again
select the appropriate operation (Heating, Cooling) to adjust the tem-
perature to the value set in the thermostat.

(The monitor operation range is ±4 °F relative to the thermostat set-
ting.)

If the mode automatically selected by the unit is not what you wish,
select one of the mode operation (HEAT, COOL, DRY, FAN).

About Mode Operation

Heating:

Use to warm your room.

When Heating mode is selected, the air conditioner will operate at very
low fan speed for about 3 to 5 minutes, after which it will switch to the
selected fan setting. This period of time is provided to allow the indoor
unit to warm up before begin full operation.

When the room temperature is very low, frost may form on the outside
unit, and its performance may be reduced. In order to remove such
frost, the unit will automatically enter the defrost cycle from time to
time. During Automatic Defrosting operation, the OPERATION Indica-
tor Lamp (Fig. 3 

5

) will flash, and the heat operation will be inter-

rupted.

After the start of heating operation, it takes some time before the room
gets warmer.

Cooling:

Use to cool your room.

Dry:

Use for gently cooling while dehumidifying your room.

You cannot heat the room during Dry mode.

During Dry mode, the unit will operate at low speed; in order to adjust
room humidity, the indoor unit’s fan may stop from time to time. Also,
the fan may operate at very low speed when adjusting room humidity.

The fan speed cannot be changed manually when Dry mode has been
selected.

Fan:

Use to circulate the air throughout your room.

During Heating mode:

Set the thermostat to a temperature set-
ting that is higher than the current room
temperature. The Heating mode will not
operate if the thermostat is set lower than
the actual room temperature.

During Cooling/Dry mode:

Set the thermostat to a temperature set-
ting that is lower than the current room
temperature. The Cooling and Dry modes
will not operate if the thermostat is set
higher than the actual room temperature
(in Cooling mode, the fan alone will oper-
ate).

During Fan mode:

You can not use the unit to heat and cool
your room.

Summary of Contents for Inverter Halcyon AOU24RL

Page 1: ......

Page 2: ......

Page 3: ......

Page 4: ... BTU h UISSANCE ABSORBÉE 2 31 kW NTENSITÉ 10 1 A UFFAGE UISSANCE FRIGORIFIQUE 27 600 BTU h UISSANCE ABSORBÉE 2 47 kW NTENSITE 10 8 A PECIFICATIONS ER SUPPLY 208 230 V 60 Hz LING APACITY 24 200 BTU h NPUT POWER 2 31 kW URRENT 10 1 A ING APACITY 27 600 BTU h NPUT POWER 2 47 kW URRENT 10 8 A EL INDOOR UNIT ÈLE UNIDAD INTERIOR ELO UNITÉ INTÉRIEURE OUTDOOR UNIT UNIDAD EXTERIOR UNITÉ EXTÉRIEURE ASU24RL ...

Page 5: ...n the room For heating use downward airflow to send powerful warm air to the floor and create a comfortable environment OMNI DIRECTIONAL AIR FLOW SWING OPERATION Three dimensional control over air direction swing is possi ble through dual use of both an UP DOWN air direction swing and RIGHT LEFT air direction swing Since UP DOWN air direction flaps operate automatically according to the oper ating...

Page 6: ...splay Fan Speed Display a Temperature SET Display b COIL DRY Display c SLEEP Display d SWING Display NAME OF PARTS Refer to the folded out page on the cover Fig 1 Indoor Unit 1 Operating Control Panel Fig 2 2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installati...

Page 7: ...e direction of the arrow while pressing the mark 2 Insert batteries Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 X Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 6 P to adjust the clock to the current time button Press to advance the time bu...

Page 8: ...TROL button Fig 6 Q Each time the button is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperat...

Page 9: ...ut 3 to 5 minutes after which it will switch to the selected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defros...

Page 10: ...econds later the entire display will reappear About the Program timer The program timer allows you to integrate OFF timer and ON timer operations in a single sequence The sequence can involve one transition from OFF timer to ON timer or from ON timer to OFF timer within a twenty four hour period The first timer function to operate will be the one set nearest to the current time The order of operat...

Page 11: ...ps During Cooling Dry operation When the SLEEP timer is set the thermostat setting is auto matically raised 2 F every sixty minutes When the thermo stat has been raised a total of 4 F the thermostat setting at that time is maintained until the set time has elapsed at which time the air conditioner automatically turns off SLEEP timer setting During Heating operation When the SLEEP timer is set the ...

Page 12: ...cally return to posi tion 3 When used in a room with infants chil dren elderly or sick persons the air direction and room temperature should be considered carefully when making settings Vertical Air Direction Adjustment Press the SET button Vertical Fig 6 S Each time the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air flow Direction Setting 1 2 3 During Co...

Page 13: ...ot get rid of the existed mould or bacterium and it has no sterilization effect either Begin air conditioner operation before performing this procedure Up down swing operation Left right swing operation Swing operation stops Up down left right swing operation About Swing Operation Up down swing Swing operation begins using the following range according to the current airflow direc tion Airflow dir...

Page 14: ...ille 1 Align the sides of the air filter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit without Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild de tergent and ...

Page 15: ...disposable filters They can not be washed and reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every three months Please buy delicated air cleaning filters UTR FA13 1 Sold separately to exchange the use...

Page 16: ...condensation and misting During Heating operation the outdoor unit s fan may stop and steam may be seen rising from the unit This is due to Automatic Defrosting operation When Heating operation is started fan speed is temporarily very low to allow internal parts to warm up During Heating operation if the room temperature rises above the thermostat setting the outdoor unit will stop and the indoor ...

Page 17: ...s If you feel that insufficient heating performance is being produced we recommend you use this air conditioner in conjunction with another kind of heating appliance Heat pump air conditioners heat your entire room by recirculating air throughout the room with the result that some time may be required after first starting the air con ditioner until the room is heated Microcomputer controlled Autom...

Page 18: ... used under conditions of lower temperature than those listed above the heat exchanger may freeze leading to water leakage and other damage Do not use this unit for any purposes other than the Cooling Dehumidifying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip o...

Page 19: ......