background image

En-5

PREPARATION

 

 CAUTION!

 Take care to prevent infants from acciden-

tally swallowing batteries.

 When not using the Remote Controller for 

an extended period, remove the batteries to 
avoid possible leakage and damage to the 
unit.

 If leaking battery fl uid comes in contact with 

your skin, eyes, or mouth, immediately wash 
with copious amounts of water, and consult 
your physician.

 Dead batteries should be removed imme-

diately and disposed of properly, either in a 
battery collection receptacle or to the appro-
priate authority.

 Do not attem pt to recharge dry batteries.

Never mix new and used batteries, or bat-
teries of different types.
Batteries should last about one year un-
der normal use. If the Remote Controller’s 
operating range becomes appreciably 
reduced, replace the batteries and press 
the RESET button with the tip of a ball-
point pen or other small object.

Load Batteries (AAA/R03/LR03 

×

 2)

1

  Press and slide the battery compartment lid on the 

reverse side to open it.

 

Slide in the direction of the arrow while pressing the 

 mark.

2

 Insert 

batteries.

 

Be sure to align the battery polarities (

) correctly.

3

  Close the battery compartment lid.

Set the Current time

1

  Press the CLOCK ADJUST button (Fig. 6 b14).

 

Use the tip of a ball-point pen or other small object to press the button.

2

  Use the TIMER SET ( 

 / 

 ) buttons (Fig. 6 b13) to 

adjust the clock to the current time.

 

   button: 

Press to advance the time.

 

   button: 

Press to reverse the time.

 

(Each time the buttons are pressed, the time will be advanced/reversed 
in one-minute increments; hold the buttons depressed to change the time 
quickly in ten-minute increments.)

3

  Press the CLOCK ADJUST button (Fig. 6 b14) again.

 

This completes the time setting and starts the clock.

To Use the Remote Controller

  The Remote Controller must be pointed at signal receiver (Fig.3 a4) to operate correctly.

  Operating Range: About 23ft (7 meters).

 When a signal is properly received by the air conditioner, a beeping sound will be 

heard.

  If no beep is heard, press the Remote Controller button again.

Remote Controller Holder

3

  To remove the Remote Con-

troller (when use at hand).

1

  Mount the Holder.

2

  Set the Remote Controller.

Screws

Insert

Press in

Slide up

Pull out

Turn on the Power

1

  Turn on the circuit breaker

9315345271_OM.indb   5

9315345271_OM.indb   5

2/10/2010   9:55:38 AM

2/10/2010   9:55:38 AM

Summary of Contents for Inverter Halcyon AOU18RLXS

Page 1: ...I MANUAL ASU18RLXS ASU24RLXS ASU30RLX AOU18RLXS AOU24RLXS AOU30RLX CONSERVEZ CE MODE D EMPLOI POUR RÉFÉRENCE ULTÉRIEUR 9315345271 9315345271_OM indb 1 9315345271_OM indb 1 2 10 2010 9 55 26 AM 2 10 2010 9 55 26 AM ...

Page 2: ... air conditioner directly to water Do not operate the air conditioner with wet hands Do not pull power supply cord Turn off power supply when not using the indoor unit for extended periods Check the condition of the installation stand for damage Do not place animals or plants in the direct path of the airflow Do not drink the water drained from the air conditioner Do not use in applications involv...

Page 3: ...ronment OMNI DIRECTIONAL AIR FLOW SWING OPERATION Three dimensional control over air direction swing is possible through dual use of both an UP DOWN air direction swing and RIGHT LEFT air direction swing Since UP DOWN air direction flaps operate automatically according to the operating mode of the unit it is possible to set air direction based on the operat ing mode REMOVABLE INTAKE GRILLE The ind...

Page 4: ...2 c4 c5 c3 c1 b1 b2 b4 b3 b5 b6 b13 b8 b9 b10 b11 b12 b7 b16 b15 b14 Fig 7 To facilitate explanation the accompanying illustration has been drawn to show all possible indicators in actu al operation however the display will only show those indicators appropriate to the current operation 9315345271_OM indb 3 9315345271_OM indb 3 2 10 2010 9 55 36 AM 2 10 2010 9 55 36 AM ...

Page 5: ...ansmit Indicator c6 Fan Speed Display c7 SWING Display c8 Timer Mode Display c9 Clock Display Fig 1 Indoor Unit a1 Operating Control Panel Fig 2 a2 MANUAL AUTO button When kept on pressing the MANUAL AUTO button for more than 10 seconds the forced cooling operation will start The forced cooling operation is used at the time of installation Only for authorized service personnel s use When the force...

Page 6: ... Be sure to align the battery polarities correctly 3 Close the battery compartment lid Set the Current time 1 Press the CLOCK ADJUST button Fig 6 b14 Use the tip of a ball point pen or other small object to press the button 2 Use the TIMER SET buttons Fig 6 b13 to adjust the clock to the current time button Press to advance the time button Press to reverse the time Each time the buttons are presse...

Page 7: ...ton is pressed the fan speed changes in the following order AUTO HIGH MED LOW QUIET About three seconds later the entire display will reappear When set to AUTO Heating Fan operates so as to optimally circulate warmed air However the fan will operate at very low speed when the temperature of the air issued from the indoor unit is low Cooling As the room temperature approaches that of the thermostat...

Page 8: ...tch to the se lected fan setting This period of time is provided to allow the indoor unit to warm up before begin full operation When the room temperature is very low frost may form on the outside unit and its performance may be reduced In order to remove such frost the unit will automatically enter the defrost cycle from time to time During Automatic Defrosting operation the OPERATION Indicator L...

Page 9: ...N timer or OFF timer to set the desired mode and times About three seconds later the entire display will reappear The indoor unit s TIMER Indicator Lamp orange Fig 3 a6 will light 3 Press the TIMER MODE button Fig 6 b6 to select the PROGRAM timer operation OFF ON or OFF ON will display The display will alternately show OFF timer and ON timer then change to show the time setting for the operation t...

Page 10: ...bout the SLEEP Timer To prevent excessive warming or cooling during sleep the SLEEP timer function automatically modifies the thermostat setting in ac cordance with the set time setting When the set time has elapsed the air conditioner completely stops During Cooling Dry operation When the SLEEP timer is set the thermostat setting is automati cally raised 2 F every sixty minutes When the thermosta...

Page 11: ... the button is pressed the air direction range will change as follows 1 2 3 4 5 6 Types of Air flow Direction Setting For better heating cooling effect it is recommended to set the air direction in the follow ing range 1 2 3 During Cooling Dry modes 4 5 6 During Heating mode The Remote Controller s display does not change Use the air direction adjustments within the ranges shown above The vertical...

Page 12: ...f ECON OMY operation is selected by pressing the ECONOMY operation button When economy operation mode is operated the room temperature will be little higher than the set temp under cooling mode and lower than set temp under heating mode Therefore the economy mode is able to save more energy than other normal mode Begin air conditioner operation before performing this procedure Up down swing operat...

Page 13: ...While MINIMUM HEAT OPERATION is in progress only Airflow Direction Set can be used How To Use the Main Unit Controls Press the MANUAL AUTO button Fig 2 a2 on the main unit control panel To stop operation press the MANUAL AUTO button Fig 2 a2 once again Controls are located inside the intake grille MANUAL AUTO OPERATION Use the MANUAL AUTO operation in the event the Remote Controller is lost or oth...

Page 14: ...ter with the panel and push in fully making sure the two lower tabs are returned properly to their holes in the panel 2 Close the Intake Grille For purposes of example the illustration shows the unit with out Intake Grille installed Dust can be cleaned from the air filter either with a vacuum cleaner or by washing the filter in a solution of mild deter gent and warm water If you wash the filter be...

Page 15: ...nd reused For storage of the Air Cleaning Filters use the filters as soon as possible after the package has been opened The air cleaning effect decreases when the filters are left in the opened package Generally the filters should be exchanged about every three months Please buy delicated air cleaning filters UTR FA13 1 Sold separately to exchange the used dirty air cleaning filters Negative air i...

Page 16: ...utomatic Defrosting operation Some smell may be emitted from the indoor unit This smell is the result of room smells furniture tobacco etc which have been taken into the air conditioner During Cooling or Dry operation a thin mist may be seen emitted from the indoor unit This results from the sudden Cooling of room air by the air emitted from the air conditioner resulting in condensa tion and misti...

Page 17: ...th another kind of heating appliance Heat pump air conditioners heat your entire room by recir culating air throughout the room with the result that some time may be required after first starting the air conditioner until the room is heated Microcomputer controlled Automatic Defrosting When using the Heating mode under conditions of low out door temperature and high humidity frost may form on the ...

Page 18: ...fying and air circulation of rooms in ordinary dwellings If the unit is used for long periods under high humidity conditions condensation may form on the surface of the indoor unit and drip onto the floor or other objects underneath About 80 or more If the outdoor temperature is lower than the temperature scope in the list above in order to keep safety operation of device the outdoor unit may stop...

Page 19: ...9315345271_OM indb 18 9315345271_OM indb 18 2 10 2010 9 55 42 AM 2 10 2010 9 55 42 AM ...

Page 20: ...9315345271_OM indb 2 9315345271_OM indb 2 2 10 2010 9 55 35 AM 2 10 2010 9 55 35 AM ...

Reviews: